CPC75282  
2.10 Thermal Shutdown  
thermal shutdown mode will continue as long as the  
fault condition persists. If the magnitude of the fault  
condition is great enough, the external secondary  
protector will activate, shunting the fault current to  
ground.  
The thermal shutdown mechanism activates when the  
device die temperature reaches a minimum of 110°C,  
placing the device in the All-Off state regardless of  
logic input. During thermal shutdown events the T  
SDx  
pin will output a logic low with a nominal 0V level. A  
logic high is output from the T pin during normal  
2.11 External Protection Elements  
SDx  
operation with a typical output level equal to V  
.
DD  
The CPC75282 requires only over-voltage secondary  
protection on the loop side of the device. The  
integrated protection feature described above negates  
the need for additional external protection on the SLIC  
side. The secondary protector must limit voltage  
transients to levels that do not exceed the breakdown  
voltage or input-output isolation barrier of the  
CPC75282. A foldback or crowbar type protector is  
recommended to minimize stresses on the  
CPC75282.  
If presented with a short duration transient, such as a  
lightning event, the thermal shutdown feature will  
typically not activate. But in an extended power-cross  
event, the device temperature will rise and the thermal  
shutdown mechanism will activate forcing the switches  
to the All-Off state. At this point the current measured  
into T  
or R  
will drop to zero. Once the device  
LINE  
LINE  
enters thermal shutdown, it will remain in the All-Off  
state until the temperature of the device drops below  
the de-activation level of the thermal shutdown circuit.  
This permits the device to autonomously return to  
normal operation. If the transient has not passed,  
current will again flow up to the value allowed by the  
dynamic DC current limiting of the switches and  
heating will resume, reactivating the thermal shutdown  
mechanism. This cycle of entering and exiting the  
Consult Clare’s application note, AN-100, “Designing  
Surge and Power Fault Protection Circuits for Solid  
State Subscriber Line Interfaces,” for equations related  
to the specifications of external secondary protectors,  
fused resistors, and PTCs.  