欢迎访问ic37.com |
会员登录 免费注册
发布采购

CPC75282KATR 参数 Datasheet PDF下载

CPC75282KATR图片预览
型号: CPC75282KATR
PDF下载: 下载PDF文件 查看货源
内容描述: 线卡接入交换机 [Line Card Access Switch]
分类和应用:
文件页数/大小: 19 页 / 667 K
品牌: CLARE [ CLARE ]
 浏览型号CPC75282KATR的Datasheet PDF文件第11页浏览型号CPC75282KATR的Datasheet PDF文件第12页浏览型号CPC75282KATR的Datasheet PDF文件第13页浏览型号CPC75282KATR的Datasheet PDF文件第14页浏览型号CPC75282KATR的Datasheet PDF文件第16页浏览型号CPC75282KATR的Datasheet PDF文件第17页浏览型号CPC75282KATR的Datasheet PDF文件第18页浏览型号CPC75282KATR的Datasheet PDF文件第19页  
CPC75282  
tied to V , the channel just ignores this input, and still  
enters the thermal shutdown state at high  
temperature.  
2.9 Protection  
2.9.1 Diode Bridge  
CC  
Both channels of the CPC75282 use a combination of  
current limited break switches, a diode bridge, and a  
thermal shutdown mechanism to protect the SLIC  
device or other associated circuitry from damage  
during line transient events, such as lightning. During  
a positive transient condition, the fault current is  
conducted through the diode bridge to ground via  
2.6 Ringing Switch Zero-Cross Current Turn Off  
After the application of a logic input to turn SW4 off,  
the ringing switch is designed to delay the change in  
state until the next zero-crossing. Once on, the switch  
requires a zero-current cross to turn off, and therefore  
should not be used to switch a pure DC signal. The  
switch will remain in the on state no matter the logic  
input until the next zero crossing. These switching  
characteristics will reduce and possibly eliminate  
overall system impulse noise normally associated with  
ringing switches. See Clare’s application note,  
AN-144, Impulse Noise Benefits of Line Card Access  
Switches, for more information. The attributes of  
ringing switch, SW4, may make it possible to eliminate  
the need for a zero-cross switching scheme. A  
minimum impedance of 300Ω in series with the ringing  
generator is recommended.  
F
. Voltage is clamped to a diode drop above  
GND  
ground. Negative lightning is directed to battery via  
steering diodes in the diode bridge. For power  
induction or power-cross fault conditions, the positive  
cycle of the transient is clamped to a diode drop above  
ground and the fault current directed to ground. The  
negative cycle of the transient is steered to battery.  
Fault currents are limited by the current-limit circuit.  
2.9.2 Current Limiting function  
If a lightning strike transient occurs when the device is  
in the Idle/Talk state, the current is passed along the  
line to the integrated protection circuitry, and restricted  
by the dynamic current limit response of the active  
switches. During the Idle/Talk state, when a 1000V  
10x1000μ s lightning pulse (GR-1089-CORE  
2.7 Power Supplies  
Both a +5V supply and battery voltage are connected  
to the CPC75282. Switch state control is powered  
exclusively by the +5V supply. As a result, the  
CPC75282 exhibits extremely low power consumption  
during active and idle states. Although battery power  
is not used for switch control, it is required to supply  
current during negative overvoltage fault conditions at  
tip and ring.  
lightning) is applied to the line though a properly  
clamped external protector, the current seen at T  
LINE  
and R  
will be a pulse with a typical magnitude of  
LINE  
2.5A and a duration less than 0.5μs.  
If a power-cross fault occurs with the device in the  
Idle/Talk state, the current is passed though break  
switches, SW1 and SW2, on to the integrated  
protection circuit, but is limited by the DC current limit  
response of the two break switches. The DC current  
limit is dependent on the switch differential voltage, as  
shown in “Figure 2: Switches 1-3” on page 17.  
Note that the current limit circuitry has a negative  
temperature coefficient. As a result, if the device is  
subjected to extended heating due to a power cross  
2.8 Battery Voltage Monitor  
The CPC75282 also uses the V  
voltage to monitor  
BAT  
battery voltage. If system battery voltage is lost, both  
channels of the CPC75282 immediately enter the  
All-Off state. It remains in this state until the battery  
voltage is restored. The device also enters the All-Off  
state if the battery voltage rises more positive than  
about –10V with respect to ground and remains in the  
All-Off state until the battery voltage drops below  
approximately –15V with respect to ground. This  
battery monitor feature draws a small current from the  
battery (less than 1μA typical) and will add slightly to  
the device’s overall power dissipation.  
fault condition, the measured current at T  
and  
LINE  
R
will decrease as the device temperature  
LINE  
increases. If the device temperature rises sufficiently,  
the temperature shutdown mechanism will activate  
and the device will enter the All-Off state.  
R00D  
www.clare.com  
15  