CS5460A  
4.1.5 Power-Down  
B7  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
1
0
0
S1  
S0  
0
0
0
The device has two power-down states to conserve power. If the chip is put in stand-by state, all circuitry except the  
analog/digital clock generators is turned off. In the sleep state, all circuitry except the digital clock generator and the  
instruction decoder is turned off. Waking up the CS5460A out of sleep state requires more time than waking the  
device out of stand-by state, because of the extra time needed to re-start and re-stabilize the analog clock signal.  
[S1 S]0  
Power-down state  
00 = Reserved  
01 = Halt and enter stand-by power saving state. This state allows quick power-on time  
10 = Halt and enter sleep power saving state. This state requires a slow power-on time  
11 = Reserved  
4.1.6 Calibration  
B7  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
1
1
0
V
I
R
G
O
The device has the capability of performing a system AC offset calibration, DC offset calibration, AC gain calibration,  
and DC gain calibration. Calibration can be done on the voltage channel, the current channel, or both channels at  
the same time. Offset and gain calibrations should NOT be performed at the same time (must do one after the oth-  
er). For a given application, if DC gain calibrations are performed, then AC gain calibration should not be performed  
(and vice-versa). The proper input voltages must be supplied to the device before initiating calibration.  
[V I]  
Designates calibration channel  
00 = Not allowed  
01 = Calibrate the current channel  
10 = Calibrate the voltage channel  
11 = Calibrate voltage and current channel simultaneously  
R
G
Specifies AC calibration (R=1) or DC calibration (R=0)  
Designates gain calibration  
0 = Normal operation  
1 = Perform gain calibration  
O
Designates offset calibration  
0 = Normal operation  
1 = Perform offset calibration  
40  