Register 0x1B (INT_MAP_2)
Controls which interrupt signals are mapped to the INT2 pin.
Name
Bit
0x1B
7
INT_MAP_2
6
5
4
Read/Write R/W
R/W
0
R/W
0
R/W
0
Reset
0
Value
Content
int2_flat
3
int2_orient
int2_s_tap
int2_d_tap
Bit
2
1
0
Read/Write R/W
R/W
0
R/W
0
R/W
0
Reset
0
Value
Content
int2_slo_no_mot
int2_slope
int2_high
int2_low
int2_flat:
map flat interrupt to INT2 pin: ‘0’disabled, or ‘1’ enabled
map orientation interrupt to INT2 pin: ‘0’disabled, or ‘1’ enabled
map single tap interrupt to INT2 pin: ‘0’disabled, or ‘1’ enabled
map double tap interrupt to INT2 pin: ‘0’disabled, or ‘1’ enabled
int2_orient:
int2_s_tap:
int2_d_tap:
int2_slo_no_mot: map slow/no-motion interrupt to INT2 pin: ‘0’disabled, or ‘1’ enabled
int2_slope:
int2_high:
int2_low:
map slope interrupt to INT2 pin: ‘0’disabled, or ‘1’ enabled
map high-g to INT2 pin: ‘0’disabled, or ‘1’ enabled
map low-g to INT2 pin: ‘0’disabled, or ‘1’ enabled