BMA253
Data sheet
Page 58
Register 0x0A (INT_STATUS_1)
The register contains interrupt status flags. Each flag is associated with a specific interrupt
function. It is set when the associated interrupt engine triggers. The setting of latch_int<3:0>
controls if the interrupt signal and hence the respective interrupt flag will be permanently
latched, temporarily latched or not latched. The interrupt function associated with a specific
status flag must be enabled.
Name
Bit
0x0A
7
INT_STATUS_1
6
5
4
Read/Write
R
R
R
R
Reset
n/a
n/a
n/a
n/a
Value
Content
data_int
fifo_wm_int
fifo_full_int
reserved
Bit
3
2
1
0
Read/Write
Reset
R
n/a
R
n/a
R
n/a
R
n/a
Value
Content
reserved
data_int:
data ready interrupt status: ‘0’inactive, ‘1’ active
FIFO watermark interrupt status: ‘0’inactive, ‘1’ active
FIFO full interrupt status: ‘0’inactive, ‘1’ active
reserved, write to ‘0’
fifo_wm_int:
fifo_full_int:
reserved:
BST-BMA253-DS000-01 | Revision 1.0 | August 2015