BMA253
Data sheet
Page 57
Register 0x09 (INT_STATUS_0)
The register contains interrupt status flags. Each flag is associated with a specific interrupt
function. It is set when the associated interrupt triggers. The setting of latch_int<3:0> controls if
the interrupt signal and hence the respective interrupt flag will be permanently latched,
temporarily latched or not latched. The interrupt function associated with a specific status flag
must be enabled.
Name
Bit
0x09
7
INT_STATUS_0
6
5
4
Read/Write
R
R
R
R
Reset
n/a
n/a
n/a
n/a
Value
Content
flat_int
orient_int
s_tap_int
d_tap_int
Bit
3
2
1
0
Read/Write
Reset
R
n/a
R
n/a
R
n/a
R
n/a
Value
Content
slo_no_mot_int
slope_int
high_int
low_int
flat_int:
flat interrupt status: ‘0’inactive, ‘1’ active
orient_int:
s_tap_int:
d_tap_int
orientation interrupt status: ‘0’inactive, ‘1’ active
single tap interrupt status: ‘0’inactive, ‘1’ active
double tap interrupt status: ‘0’inactive, ‘1’ active
slo_not_mot_int: slow/no-motion interrupt status: ‘0’inactive, ‘1’ active
slope_int:
high_int:
low_int:
slope interrupt status: ‘0’inactive, ‘1’ active
high-g interrupt status: ‘0’inactive, ‘1’ active
low-g interrupt status: ‘0’inactive, ‘1’ active
BST-BMA253-DS000-01 | Revision 1.0 | August 2015
Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to
third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.