SBAS288D − JUNE 2003 − REVISED AUGUST 2004  
System Calibration  
SERIAL INTERFACE  
System calibration corrects both internal and external  
offset and gain errors using the SYSOCAL and SYSGCAL  
commands. During system calibration, the appropriate  
calibration signals must be applied by the user to the  
inputs.  
The SPI-compatible serial interface consists of four  
signals: CS, SCLK, DIN, and DOUT, and allows a  
controller to communicate with the ADS1255/6. The  
programmable functions are controlled using a set of  
on-chip registers. Data is written to and read from these  
registers via the serial interface  
SYSOCAL performs a system offset calibration. The user  
must supply a zero input differential signal. The  
ADS1255/6 then computes a value that will nullify the  
offset in the system. Table 22 shows the time required for  
system offset calibration for the different data rate settings.  
Note this timing is the same for the self offset calibration.  
System offset calibration updates the OFC register.  
The DRDY output line is used as a status signal to indicate  
when a conversion has been completed. DRDY goes low  
when new data is available. The Timing Specification  
shows the timing diagram for interfacing to the  
ADS1255/6.  
SYSGCAL performs a system gain calibration. The user  
must supply a full-scale input signal to the ADS1255/6.  
The ADS1255/6 then computes a value to nullify the gain  
error in the system. System gain calibration can correct  
inputs that are 80% of the full-scale input voltage and  
larger. Make sure not to exceed the full-scale input voltage  
when using system gain calibration. Table 22 shows the  
time required for system gain calibration for the different  
data rate settings. System gain calibration updates the  
FSC register.  
CHIP SELECT (CS)  
The chip select (CS) input allows individual selection of a  
ADS1255/6 device when multiple devices share the serial  
bus. CS must remain low for the duration of the serial  
communication. When CS is taken high, the serial  
interface is reset and DOUT enters a high impedance  
state. CS may be permanently tied low.  
SERIAL CLOCK (SCLK)  
The serial clock (SCLK) features a Schmitt-triggered input  
and is used to clock data on the DIN and DOUT pins into  
and out of the ADS1255/6. Even though the input has  
hysteresis, it is recommended to keep SCLK as clean as  
possible to prevent glitches from accidentally shifting the  
data. If SCLK is held low for 32 DRDY periods, the serial  
interface will reset and the next SCLK pulse will start a new  
communication cycle. This timeout feature can be used to  
recover communication when a serial interface transmis-  
sion is interrupted. A special pattern on SCLK will reset the  
chip; see the RESET section for more details on this  
procedure.  
Table 22. System Gain Calibration Timing  
DATA RATE  
SYSTEM GAIN CALIBRATION TIME  
(SPS)  
30,000  
15,000  
7500  
3750  
2000  
1000  
500  
100  
60  
417µs  
484µs  
617µs  
884µs  
1.4ms  
2.4ms  
4.4ms  
20.4ms  
33.7ms  
40.4ms  
67.0ms  
80.4ms  
133.7ms  
200.4ms  
400.4ms  
800.4ms  
DATA INPUT (DIN) AND DATA OUTPUT (DOUT)  
The data input pin (DIN) is used along with SCLK to send  
data to the ADS1255/6. The data output pin (DOUT) along  
with SCLK is used to read data from the ADS1255/6. Data  
on DIN is shifted into the part on the falling edge of SCLK  
while data is shifted out on DOUT on the rising edge of  
SCLK. DOUT is high impedance when not in use to allow  
DIN and DOUT to be connected together and be driven by  
a bi-directional bus. Note: the RDATAC command must  
not be issued while DIN and DOUT are connected  
together.  
50  
30  
25  
15  
10  
5
2.5  
NOTE: For f  
= 7.68MHz.  
CLKIN  
Auto-Calibration  
Auto-calibration can be enabled (ACAL bit in ADCON  
register) to have the ADS1255/6 automatically initiate a  
self-calibration at the completion of a write command  
(WREG) that changes the data rate, PGA setting, or Buffer  
status.  
26  