 浏览型号B10011S-MFPG3Y74的Datasheet PDF文件第1页浏览型号B10011S-MFPG3Y74的Datasheet PDF文件第2页浏览型号B10011S-MFPG3Y74的Datasheet PDF文件第3页浏览型号B10011S-MFPG3Y74的Datasheet PDF文件第5页浏览型号B10011S-MFPG3Y74的Datasheet PDF文件第6页浏览型号B10011S-MFPG3Y74的Datasheet PDF文件第7页浏览型号B10011S-MFPG3Y74的Datasheet PDF文件第8页浏览型号B10011S-MFPG3Y74的Datasheet PDF文件第9页  
3. Absolute Maximum Ratings  
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating  
only and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of this  
specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.  
Parameters  
Symbol  
VCC  
VDD  
Vin  
Value  
–0.5 to +36  
–0.5 to +5.5  
–0.5 to VDD  
150  
Unit  
V
Supply voltage  
Controller supply voltage  
Input voltage at any input  
Junction temperature  
V
V
Tj  
°C  
°C  
°C  
Storage temperature range  
Soldering temperature (for 10s maximum)  
Tstg  
–55 to +150  
260  
Tsld  
Operating Conditions  
Parameters  
Symbol  
VCC  
Value  
7 to 32  
Unit  
V
Supply voltage car battery  
Controller supply voltage  
Control input voltage  
Input voltage  
VDD  
4.75 to 5.25  
0 to VDD  
V
Asel, Bsel  
Tx0  
V
0 to VDD  
V
Operating temperature  
Tamb  
–40 to +105  
°C  
4. Operating Modes  
0 = 0V, 1 = 5V  
Asel  
Bsel  
Rx0  
Mode  
H, L drivers disabled, L load disabled, S-, S+ disabled station not in operation, but  
consuming current  
0
0
3.8V  
1
0
1
0
1
1
From H  
From L  
Single-wire H, L driver, L load, S-, S+ disabled  
Single-wire L, H driver disabled  
From L-H  
Two-wire operation, normal mode  
ER (error signal) is low when normal operation is disturbed by line faults (interruption, short to  
ground or to VCC, H to L short disturbance by high voltage transients). After a waiting period due  
to transient delays, the controller is asked to test if single-wire operation is possible by changing  
the Asel and Bsel state.  
A
sel and Bsel have an internal pull-up resistor. Therefore, the no-connect state is 1, but connec-  
tion to VDD is recommended when not in use.  
4
B10011S  
4749D–AUTO–10/07  