17–2
Chapter 17: Understanding and Evaluating Power in MAX II Devices
Power in MAX II Devices
Figure 17–1. Power Consumption versus Frequency for MAX II Devices (Note 1), (2)
EPM240
EPM570
(3)
(4)
(3)
250.00
200.00
150.00
100.00
50.00
120.00
100.00
80.00
(4)
60.00
40.00
(5)
(6)
(5)
(6)
20.00
0.00
0.00
0
100
50
Frequency (MHz)
0
100
150
150
50
Frequency (MHz)
1000.00
900.00
800.00
700.00
600.00
500.00
400.00
300.00
200.00
EPM2210
EPM1270
(3)
(4)
600.00
(3)
(4)
500.00
400.00
300.00
200.00
100.00
0.00
(5)
(5)
100.00
0.00
0
100
50
Frequency (MHz)
150
0
100
50
Frequency (MHz)
150
Notes to Figure 17–1:
(1) Every device is fully utilized with 16-bit counters for power estimation.
(2) The MAX II and MAX IIG devices can operate up to 304 MHz.
(3) VCCINT = 3.3 V
(4) VCCINT = 2.5 V
(5) VCCINT = 1.8 V (MAX IIG)
(6) VCCINT = 1.8 V (MAX IIZ)
The power consumed in MAX II devices is dependent on the design. It is very
important to complete a power evaluation early in the design process to ensure that
the power dissipation by MAX II devices meets system requirements and
specifications.
This chapter discusses how to evaluate and manage MAX II power using the MAX II
PowerPlay Early Power Estimator spreadsheet, available at www.altera.com.
MAX II Device Handbook
© October 2008 Altera Corporation