 浏览型号EPM240T100C5N的Datasheet PDF文件第279页浏览型号EPM240T100C5N的Datasheet PDF文件第280页浏览型号EPM240T100C5N的Datasheet PDF文件第281页浏览型号EPM240T100C5N的Datasheet PDF文件第282页浏览型号EPM240T100C5N的Datasheet PDF文件第284页浏览型号EPM240T100C5N的Datasheet PDF文件第285页浏览型号EPM240T100C5N的Datasheet PDF文件第286页浏览型号EPM240T100C5N的Datasheet PDF文件第287页  
Chapter 17: Understanding and Evaluating Power in MAX II Devices
PowerPlay Early Power Estimator Inputs
17–5
Table 17–1.
Input Parameter Section Information (Part 2 of 2)
Input Parameter
V
CCINT
Supply
Description
The voltage of the V
CCINT
power supply. For MAX IIG and MAX IIZ devices, the supply voltage must
be 1.8 V. For other devices, it can be either 2.5 V or 3.3 V. Devices with lower V
CCINT
have lower total
standby power consumption.
Enter the air temperature near the CPLD. This value can range from –40°C to 125°C, depending on
the device temperature grade. This parameter is used to compute junction temperature based on
power dissipation and thermal resistances through the top of the chip.
Select an available ambient airflow in linear feet per minute (lfm) or meters per second (m/s). The
options are still air, 100 lfm (0.5 m/s), 200 lfm (1.0 m/s), or 400 lfm (2.0 m/s). Increased airflow
results in a lower junction-to-air thermal resistance, and thus lower junction temperature.
Ambient Temperature
Airflow
Clock Section
MAX II devices have four global clocks each. Each row in the Clock Domain
subsection of the spreadsheet represents a clock network or a separate clock domain.
You must enter the clock frequency (f
MAX
) in MHz, the total fan-out for each clock
network used, and the local clock enable percentage.
shows the Clock
section in the PowerPlay Early Power Estimator spreadsheet.
Figure 17–4.
Clock Section
describes the parameters in the Clock section of the PowerPlay Early
Power Estimator spreadsheet.
Table 17–2.
Clock Section Information
Column Heading
Clock Domain
Clock Frequency (MHz)
Total Fanout
Description
Enter a name for the clock network in this column (optional entry).
Enter the frequency of the clock domain. The operating frequency for MAX II and MAX IIG is
between 0 and 304 MHz. For MAX IIZ, the operating frequency is between 0 and 152 MHz.
Enter the total number of logic element (LE) flipflops fed by this clock. The number of
resources driven by every global clock is reported in the Fanout column of the Quartus II
Compilation Report under Fitter > Resource Section > Global & Other Fast Signals > Fanout.
Enter the average percentage of time that clock enable is high for destination flipflops. Local
clock enables for flipflops in the LEs are promoted to logic array block (LAB)-wide signals.
When a given flipflop is disabled, the LAB-wide clock is also disabled, cutting clock power in
addition to power for downstream logic. This sheet models only the impact on clock tree
power.
Represents the total power dissipation due to clock distribution.
Enter any comments (optional entry).
Local Enable %
Total Power (mW)
User Comments