Serial Configuration Devices (EPCS1, EPCS4, EPCS16 & EPCS64) Data Sheet
Tables 4–15 through 4–19 provide information on absolute maximum
ratings, recommended operating conditions, DC operating conditions,
and capacitance for serial configuration devices.
Operating
Conditions
Table 4–15. Absolute Maximum Ratings
Symbol Parameter
Note (1)
Condition
Min
−0.6
−0.6
Max
4.0
4.0
15
Unit
V
VCC
Supply voltage
With respect to ground
With respect to ground
VI
DC input voltage
V
IMAX
IOUT
PD
DC VCC or GND current
DC output current per pin
Power dissipation
mA
mA
mW
° C
° C
° C
−25
25
54
TSTG
TAMB
TJ
Storage temperature
Ambient temperature
Junction temperature
No bias
−65
−65
150
135
135
Under bias
Under bias
Table 4–16. Recommended Operating Conditions
Symbol
VCC
VI
Parameter
Conditions
Min
Max
Unit
Supply voltage
(2)
3.0
−0.3
0
3.6
V
V
Input voltage
Respect to GND
0.3 + VCC
VO
Output voltage
VCC
70
85
5
V
TA
Operating temperature
For commercial use
For industrial use
0
° C
° C
ns
ns
−40
tR
tF
Input rise time
Input fall time
5
Table 4–17. DC Operating Conditions
Symbol
VIH
Parameter
High-level input voltage
Low-level input voltage
High-level output voltage
Low-level output voltage
Input leakage current
Conditions
Min
0.7 × VCC
−0.5
Max
Unit
V
VCC + 0.4
0.3 × VCC
VIL
V
VOH
VOL
II
IOH = −100 µA (3)
IOL = 1.6 mA (3)
VI = VCC or GND
VCC −0.2
V
0.4
10
10
V
−10
−10
µA
µA
IOZ
Tri-state output off-state current VO = VCC or GND
Altera Corporation
July 2004
Core Version a.b.c variable
4–29
Configuration Handbook, Volume 2