 浏览型号EP3C16Q144C6ES的Datasheet PDF文件第253页浏览型号EP3C16Q144C6ES的Datasheet PDF文件第254页浏览型号EP3C16Q144C6ES的Datasheet PDF文件第255页浏览型号EP3C16Q144C6ES的Datasheet PDF文件第256页浏览型号EP3C16Q144C6ES的Datasheet PDF文件第258页浏览型号EP3C16Q144C6ES的Datasheet PDF文件第259页浏览型号EP3C16Q144C6ES的Datasheet PDF文件第260页浏览型号EP3C16Q144C6ES的Datasheet PDF文件第261页  
Chapter 11: SEU Mitigation in the Cyclone III Device Family
Error Detection Timing
11–5
shows the block diagram of the error detection block and the two related
32-bit registers: the signature register and the storage register.
Figure 11–1. Error Detection Block Diagram
Error Detection
State Machine
Control Signals
Compute & Compare
CRC
32
32
32-bit Storage
Register
32-bit Signature
Register
32
lists the registers shown in
Table 11–4. Error Detection Registers
Register
Function
This register contains the CRC signature. The signature register contains the result of the user
mode calculated CRC value compared against the pre-calculated CRC value. If no errors are
detected, the signature register is all zeros. A non-zero signature register indicates an error in the
configuration CRAM contents.
The
CRC_ERROR
signal is derived from the contents of this register.
This register is loaded with the 32-bit pre-computed CRC signature at the end of the configuration
stage. The signature is then loaded into the 32-bit CRC circuit (called the Compute and Compare
CRC block, as shown in
during user mode to calculate the CRC error. This register
forms a 32-bit scan chain during execution of the
CHANGE_EDREG
JTAG instruction. The
CHANGE_EDREG
JTAG instruction can change the content of the storage register. Therefore, the
functionality of the error detection CRC circuitry is checked in-system by executing the instruction
to inject an error during the operation. The operation of the device is not halted when issuing the
CHANGE_EDREG
instruction.
32-bit signature
register
32-bit storage register
Error Detection Timing
When the error detection CRC feature is enabled through the Quartus II software, the
device automatically activates the CRC process upon entering user mode after
configuration and initialization is complete.
The
CRC_ERROR
pin is driven low until the error detection circuitry has detected a
corrupted bit in the previous CRC calculation. After the pin goes high, it remains high
during the next CRC calculation. This pin does not log the previous CRC calculation.
If the new CRC calculation does not contain any corrupted bits, the
CRC_ERROR
pin is
driven low. The error detection runs until the device is reset.
The error detection circuitry runs off an internal configuration oscillator with a divisor
that sets the maximum frequency.
December 2011
Altera Corporation
Cyclone III Device Handbook
Volume 1