欢迎访问ic37.com |
会员登录 免费注册
发布采购

EP1SGX40GF1020I6N 参数 Datasheet PDF下载

EP1SGX40GF1020I6N图片预览
型号: EP1SGX40GF1020I6N
PDF下载: 下载PDF文件 查看货源
内容描述: [Field Programmable Gate Array, 4697 CLBs, 41250-Cell, CMOS, PBGA1020, 33 X 33 MM, 1 MM PITCH, LEAD FREE, FBGA-1020]
分类和应用: 可编程逻辑
文件页数/大小: 279 页 / 3682 K
品牌: ALTERA [ ALTERA CORPORATION ]
 浏览型号EP1SGX40GF1020I6N的Datasheet PDF文件第191页浏览型号EP1SGX40GF1020I6N的Datasheet PDF文件第192页浏览型号EP1SGX40GF1020I6N的Datasheet PDF文件第193页浏览型号EP1SGX40GF1020I6N的Datasheet PDF文件第194页浏览型号EP1SGX40GF1020I6N的Datasheet PDF文件第196页浏览型号EP1SGX40GF1020I6N的Datasheet PDF文件第197页浏览型号EP1SGX40GF1020I6N的Datasheet PDF文件第198页浏览型号EP1SGX40GF1020I6N的Datasheet PDF文件第199页  
Configuration & Testing  
Partial Reconfiguration  
The enhanced PLLs within the Stratix GX device family support partial  
reconfiguration of their multiply, divide, and time delay settings without  
reconfiguring the entire device. You can use either serial data from the  
logic array or regular I/O pins to program the PLL’s counter settings in a  
serial chain. This option provides considerable flexibility for frequency  
synthesis, allowing real-time variation of the PLL frequency and delay.  
The rest of the device is functional while reconfiguring the PLL. See the  
Stratix GX Architecture chapter of the Stratix GX Device Handbook,  
Volume 1 for more information on Stratix GX PLLs.  
Remote Update Configuration Modes  
Stratix GX devices also support remote configuration using an Altera  
enhanced configuration device (for example, EPC16, EPC8, and EPC4  
devices) with page mode selection. Factory configuration data is stored in  
the default page of the configuration device. This is the default  
configuration which contains the design required to control remote  
updates and handle or recover from errors. You write the factory  
configuration once into the flash memory or configuration device.  
Remote update data can update any of the remaining pages of the  
configuration device. If there is an error or corruption in a remote update  
configuration, the configuration device reverts back to the factory  
configuration information.  
There are two remote configuration modes: remote and local  
configuration. You can use the remote update configuration mode for all  
three configuration modes: serial, parallel synchronous, and parallel  
asynchronous. Configuration devices (for example, EPC16 devices) only  
support serial and parallel synchronous modes. Asynchronous parallel  
mode allows remote updates when an intelligent host is used to configure  
the Stratix GX device. This host must support page mode settings similar  
to an EPC16 device.  
Remote Update Mode  
When the Stratix GX device is first powered-up in remote update  
programming mode, it loads the configuration located at page  
address 000. The factory configuration should always be located at page  
address 000, and should never be remotely updated. The factory  
configuration contains the required logic to perform the following  
operations:  
Determine the page address/load location for the next application’s  
configuration data  
Recover from a previous configuration error  
Altera Corporation  
February 2005  
5–3  
Stratix GX Device Handbook, Volume 1  
 复制成功!