 浏览型号EP1SGX40GF1020I6N的Datasheet PDF文件第192页浏览型号EP1SGX40GF1020I6N的Datasheet PDF文件第193页浏览型号EP1SGX40GF1020I6N的Datasheet PDF文件第194页浏览型号EP1SGX40GF1020I6N的Datasheet PDF文件第195页浏览型号EP1SGX40GF1020I6N的Datasheet PDF文件第197页浏览型号EP1SGX40GF1020I6N的Datasheet PDF文件第198页浏览型号EP1SGX40GF1020I6N的Datasheet PDF文件第199页浏览型号EP1SGX40GF1020I6N的Datasheet PDF文件第200页  
Configuration  
Receive new configuration data and write it into the configuration  
device  
The factory configuration is the default and takes control if an error  
occurs while loading the application configuration.  
While in the factory configuration, the factory-configuration logic  
performs the following operations:  
Loads a remote update-control register to determine the page  
address of the new application configuration  
Determines whether to enable a user watchdog timer for the  
application configuration  
Determines what the watchdog timer setting should be if it is  
enabled  
The user watchdog timer is a counter that must be continually reset  
within a specific amount of time in the user mode of an application  
configuration to ensure that valid configuration occurred during a  
remote update. Only valid application configurations designed for  
remote update can reset the user watchdog timer in user mode. If a valid  
application configuration does not reset the user watchdog timer in a  
specific amount of time, the timer updates a status register and loads the  
factory configuration. The user watchdog timer is automatically disabled  
for factory configurations.  
If an error occurs in loading the application configuration, the  
configuration logic writes a status register to specify the cause of the  
reconfiguration. Once this occurs, the Stratix GX device automatically  
loads the factory configuration, which reads the status register and  
determines the reason for reconfiguration. Based on the reason, the  
factory configuration takes appropriate steps and writes the remote  
update control register to specify the next application configuration page  
to be loaded.  
When the Stratix GX device successfully loads the application  
configuration, it enters into user mode. The Stratix GX device then  
executes the main application of the user. Intellectual property (IP), such  
as a Nios® embedded processor, can help the Stratix GX device determine  
when remote update is coming. The Nios embedded processor or user  
logic receives incoming data, writes it to the configuration device, and  
loads the factory configuration. The factory configuration reads the  
remote update status register and determine the valid application  
configuration to load. Figure 5–1 shows the Stratix GX remote update.  
Figure 5–2 shows the transition diagram for remote update mode.  