欢迎访问ic37.com |
会员登录 免费注册
发布采购

5CSEA2 参数 Datasheet PDF下载

5CSEA2图片预览
型号: 5CSEA2
PDF下载: 下载PDF文件 查看货源
内容描述: 旋风V器件手册 [Cyclone V Device Handbook]
分类和应用:
文件页数/大小: 74 页 / 1776 K
品牌: ALTERA [ ALTERA CORPORATION ]
 浏览型号5CSEA2的Datasheet PDF文件第54页浏览型号5CSEA2的Datasheet PDF文件第55页浏览型号5CSEA2的Datasheet PDF文件第56页浏览型号5CSEA2的Datasheet PDF文件第57页浏览型号5CSEA2的Datasheet PDF文件第59页浏览型号5CSEA2的Datasheet PDF文件第60页浏览型号5CSEA2的Datasheet PDF文件第61页浏览型号5CSEA2的Datasheet PDF文件第62页  
2–28  
Chapter 2: Device Datasheet for Cyclone V Devices  
Configuration Specification  
FPP Configuration Timing when DCLK to DATA[] = 1  
Figure 2–2 shows the timing waveform for an FPP configuration when using a  
MAX® II device as an external host. This waveform shows timing when the  
DCLK-to-DATA[]ratio is 1.  
1
When you enable decompression or the design security feature, the DCLK-to-DATA[]  
ratio varies for FPP x8 and FPP x16. For the respective DCLK-to-DATA[]ratio, refer to  
Table 2–33 on page 2–27.  
Figure 2–2. DCLK-to-DATA[] FPP Configuration Timing Waveform for Cyclone V Devices When the Ratio is 1 (1)  
tCF2ST1  
tCFG  
tCF2CK  
nCONFIG  
nSTATUS (2)  
tSTATUS  
(6)  
tCF2ST0  
tCLK  
CONF_DONE (3)  
t
CH tCL  
tCF2CD  
tST2CK  
(4)  
DCLK  
tDH  
Word 0 Word 1 Word 2 Word 3  
Word n  
Word n-2 Word n-1  
DATA[15..0](5)  
User Mode  
User Mode  
tDSU  
High-Z  
User I/O  
(7)  
INIT_DONE  
tCD2UM  
Notes to Figure 2–2:  
(1) The beginning of this waveform shows the device in user mode. In user mode, nCONFIG  
, nSTATUS, and CONF_DONEare at logic-high levels. When  
nCONFIGis pulled low, a reconfiguration cycle begins.  
(2) After power up, the Cyclone V device holds nSTATUSlow for the time of the POR delay.  
(3) After power up, before and during configuration, CONF_DONEis low.  
(4) Do not leave DCLKfloating after configuration. You can drive it high or low, whichever is more convenient.  
(5) For FPP x16, use DATA[15..0]. For FPP x8, use DATA[7..0]. DATA[15..0]are available as a user I/O pin after configuration. The state of this  
pin depends on the dual-purpose pin settings.  
(6) To ensure a successful configuration, send the entire configuration data to the Cyclone V device. CONF_DONEis released high when the Cyclone V  
device receives all the configuration data successfully. After CONF_DONEgoes high, send two additional falling edges on DCLKto begin initialization  
and enter user mode.  
(7) After the option bit to enable the INIT_DONEpin is configured into the device, INIT_DONE goes low.  
Cyclone V Device Handbook  
February 2012 Altera Corporation  
Volume 1: Device Overview and Datasheet