欢迎访问ic37.com |
会员登录 免费注册
发布采购

5CSEA2 参数 Datasheet PDF下载

5CSEA2图片预览
型号: 5CSEA2
PDF下载: 下载PDF文件 查看货源
内容描述: 旋风V器件手册 [Cyclone V Device Handbook]
分类和应用:
文件页数/大小: 74 页 / 1776 K
品牌: ALTERA [ ALTERA CORPORATION ]
 浏览型号5CSEA2的Datasheet PDF文件第56页浏览型号5CSEA2的Datasheet PDF文件第57页浏览型号5CSEA2的Datasheet PDF文件第58页浏览型号5CSEA2的Datasheet PDF文件第59页浏览型号5CSEA2的Datasheet PDF文件第61页浏览型号5CSEA2的Datasheet PDF文件第62页浏览型号5CSEA2的Datasheet PDF文件第63页浏览型号5CSEA2的Datasheet PDF文件第64页  
2–30  
Chapter 2: Device Datasheet for Cyclone V Devices  
Configuration Specification  
FPP Configuration Timing when DCLK to DATA[] > 1  
Figure 2–3 shows the timing waveform for an FPP configuration when using a  
MAX II device or microprocessor as an external host. This waveform shows timing  
when the DCLK-to-DATA[]ratio is more than 1.  
(1), (2)  
Figure 2–3. FPP Configuration Timing Waveform for Cyclone V Devices When the DCLK-to-DATA[] Ratio is > 1  
tCF2ST1  
tCFG  
tCF2CK  
nCONFIG  
nSTATUS (3)  
tSTATUS  
tCF2ST0  
CONF_DONE (4)  
t
CL  
tCF2CD  
(8)  
tST2CK  
t
CH  
DCLK (6)  
DATA[15..0] (8)  
User I/O  
(7)  
(5)  
1
2
1
1
2
r
1
2
r
r
t
CLK  
n
Word 0  
Word 1  
Word (n-1) Word  
User Mode  
User Mode  
Word 3  
t
t
tDSU  
DH  
DH  
High-Z  
(9)  
INIT_DONE  
tCD2UM  
Notes to Figure 2–3:  
(1) To find the DCLK-to-DATA[]ratio for your system, refer to Table 2–33 on page 2–27.  
(2) The beginning of this waveform shows the device in user mode. In user mode, nCONFIG, nSTATUS, and CONF_DONEare at logic high levels.  
When nCONFIGis pulled low, a reconfiguration cycle begins.  
(3) After power up, the Cyclone V device holds nSTATUSlow for the time as specified by the POR delay.  
(4) After power up, before and during configuration, CONF_DONEis low.  
(5) Do not leave DCLKfloating after configuration. You can drive it high or low, whichever is more convenient.  
(6) “r” denotes the DCLK-to-DATA[]ratio. For the DCLK-to-DATA[]ratio based on the decompression and the design security feature enable  
settings, refer to Table 2–33 on page 2–27.  
(7) If needed, pause DCLKby holding it low. When DCLKrestarts, the external host must provide data on the DATA[15..0]pins prior to sending  
the first DCLKrising edge.  
(8) To ensure a successful configuration, send the entire configuration data to the Cyclone V device. CONF_DONEis released high after the Cyclone V  
device receives all the configuration data successfully. After CONF_DONEgoes high, send two additional falling edges on DCLKto begin  
initialization and enter user mode.  
(9) After the option bit to enable the INIT_DONEpin is configured into the device, INIT_DONEgoes low.  
Cyclone V Device Handbook  
February 2012 Altera Corporation  
Volume 1: Device Overview and Datasheet