Insulation and Safety Related Specifications  
Parameter  
Symbol Value Units  
Conditions  
Min. External Clearance  
(External Air Gap)  
L(IO1)  
9.6  
10.0  
1.0  
mm  
mm  
mm  
Measured from input terminals to output  
terminals, shortest distance through air  
Min. External Creepage  
(External Tracking Path)  
L(IO2)  
Measured from input terminals to output  
terminals, shortest distance path along body  
Min. Internal Clearance  
(Internal Plastic Gap)  
Through insulation distance conductor to  
conductor, usually the direct distance  
between the photoemitter and photodetector  
inside the optocoupler cavity  
Min. Internal Creepage  
(Internal Tracking Path)  
4.0  
mm  
V
The shortest distance around the border  
between two different insulating materials  
measured between the emitter and detector  
Comparative Tracking Index  
Isolation Group  
CTI  
200  
IIIa  
DIN IEC 112/VDE 0303 PART 1  
Material group (DIN VDE 0110)  
Option 300 – surface mount classification is Class A in accordance with CECC 00802.  
VDE 0884 (06.92) Insulation Characteristics (Option #050 Only)  
Description  
Symbol  
Characteristic  
Unit  
Installation classification per DIN VDE 0110/1.89, Table 1  
For rated mains voltage 600 V rms  
I-IV  
I-III  
For rated mains voltage 1000 V rms  
Climatic Classification (DIN IEC 68 part 1)  
Pollution Degree (DIN VDE 0110 Part 1/1.89)  
Maximum Working Insulation Voltage  
55/100/21  
2
V
1414  
2651  
V peak  
V peak  
IORM  
Input to Output Test Voltage, Method b*  
VPR = 1.875 x VIORM, 100% Production Test with  
tm = 1 sec, Partial Discharge < 5 pC  
VPR  
Input to Output Test Voltage, Method a*  
VPR = 1.5 x VIORM, Type and sample test, tm = 60 sec,  
Partial Discharge < 5 pC  
VPR  
2121  
8000  
V peak  
V peak  
Highest Allowable Overvoltage*  
V
IOTM  
(Transient Overvoltage, tini = 10 sec)  
Safety-Limiting Values  
(Maximum values allowed in the event of a failure,  
also see Figure 11)  
Case Temperature  
Current (Input Current IF, PS = 0)  
Output Power  
TS  
IS  
150  
400  
700  
°C  
mA  
mW  
PS,OUTPUT  
Insulation Resistance at TS, VIO = 500 V  
RS  
>109  
*Refer to the front of the Optocoupler section of the current catalog for a more detailed description of VDE 0884 and other product  
safety regulations.  
Note: Optocouplers providing safe electrical separation per VDE 0884 do so only within the safety-limiting values to which they are  
qualified. Protective cut-out switches must be used to ensure that the safety limits are not exceeded.  