T9000  
Preliminary Data Sheet  
November 2000  
ISDN Network Termination Node (NTN) Device  
8 Device Operation Control  
8.1 Device Operation Register  
Table 41. DOCR: Device Operation Control Register (0x50)  
Reg  
R/W  
Bit 7  
Bit 6  
BS_E  
0
Bit 5  
Bit 4  
Bit 3  
NT_LT  
0
Bit 2  
Bit 1  
Bit 0  
DOCR  
R/W  
FORCE_SAI_STD  
RESET Default  
0
0
0
0
0
0
Bit #  
Symbol  
Name/Description  
7
FORCE_SAI_STD FORCE SAI Bit to Follow ETSI Standard. Controls the value of the upstream SAI  
bit, as may be required when conformance testing with a Siemens* K1404 U-inter-  
face tester.  
0: When this bit is set to 0, the SAI bit upstream remains high during the period  
from RXINFO1 going low to RXINFO3 going high, so the Siemens K1404 will  
not initiate U-only activation when TE-initiated activation is being tested.  
1: When this bit is set to 1, the SAI bit remains low conforming to the ETSI ETR  
080 standard.  
6
Backswing Suppression Enable. This bit enables the backswing suppression  
feature on the S/T-interface. It is recommended that this bit be programmed to 0.  
BS_E  
0: Backswing suppression enabled.  
1: Backswing suppression not used.  
5—4  
3
Reserved. Program to 0.  
NT_LT  
NT or LT Operation of the NTN Device. This bit selects the NT or LT operation of  
the device. This bit defaults to 0, selecting NT mode. When programmed to 1, the  
NTN device is in LT mode. When set to LT mode, GPIO2.6 is the input (regardless  
of the GPDIR2 value) for the 8 kHz MTC signal.  
2—0  
Reserved. Program to 0.  
* Siemens is a trademark of Siemens Aktiengesellschaft.  
Table 42. B1UP: B1-Channel Upstream Data from GCI to U-Interface (0x51)  
Reg  
R/W  
Bit 7  
B1UP7  
Bit 6  
B1UP6  
Bit 5  
B1UP5  
Bit 4  
B1UP4  
Bit 3  
B1UP3  
Bit 2  
B1UP2  
Bit 1  
B1UP1  
Bit 0  
B1UP0  
B1UP  
R/W  
RESET Default  
Bit #  
Symbol  
Name/Description  
7—0  
B1UP[7:0]  
B1-Channel Upstream Data. When DFR[U_FORCE_B1UP] = 1, DFR[B1_SEL] = 1, and  
ECR0[LB1] = 0, the microcontroller can write into this register the content that the user  
wants to be transferred on the upstream B1 channel from GCI to the U-interface.  
Lucent Technologies Inc.  