ADV7180  
PFTOGDELO, PAL Field Toggle Delay on Odd Field,  
Address 0xEA [7]  
1
PVENDSIGN  
0
When PFTOGDELO is 0 (default), there is no delay.  
ADVANCE END OF  
DELAY END OF VSYNC  
BY PVEND[4:0]  
VSYNC BY PVEND[4:0]  
Setting PFTOGDELO to 1 delays the F toggle/transition on an  
odd field by a line relative to PFTOG.  
NOT VALID FOR USER  
PROGRAMMING  
PFTOGDELE, PAL Field Toggle Delay on Even Field,  
Address 0xEA [6]  
ODD FIELD?  
YES  
NO  
When PFTOGDELE is 0, there is no delay.  
Setting PFTOGDELE to 1 (default) delays the F toggle/transition  
on an even field by a line relative to PFTOG.  
PVENDDELO  
1
PVENDDELE  
1
PFTOGSIGN, PAL Field Toggle Sign, Address 0xEA [5]  
0
0
Setting PFTOGSIGN to 0 delays the field transition. Set for user  
manual programming.  
ADDITIONAL  
DELAY BY  
1 LINE  
ADDITIONAL  
DELAY BY  
1 LINE  
Setting PFTOGSIGN to 1 (default) advances the field transition.  
Not recommended for user programming.  
PFTOG, PAL Field Toggle, Address 0xEA [4:0]  
VSEHO  
1
VSEHE  
1
The default value of PFTOG is 00011, indicating the PAL field  
toggle position.  
0
0
For all NTSC/PAL field timing controls, the F bit in the AV  
code and the field signal on the FIELD/DE pin are modified.  
ADVANCE BY  
0.5 LINE  
ADVANCE BY  
0.5 LINE  
1
PFTOGSIGN  
0
VSYNC END  
ADVANCE TOGGLE OF  
FIELD BY PFTOG[4:0]  
DELAY TOGGLE OF  
FIELD BY PFTOG[4:0]  
Figure 41. PAL Vsync End  
PVENDDELO, PAL Vsync End Delay on Odd Field,  
Address 0xE9 [7]  
NOT VALID FOR USER  
PROGRAMMING  
ODD FIELD?  
When PVENDDELO is 0 (default), there is no delay.  
YES  
NO  
Setting PVENDDELO to 1 delays vsync going low on an odd  
field by a line relative to PVEND.  
PFTOGDELO  
1
PFTOGDELE  
1
PVENDDELE, PAL Vsync End Delay on Even Field,  
Address 0xE9 [6]  
0
0
When PVENDDELE is 0 (default), there is no delay.  
ADDITIONAL  
DELAY BY  
1 LINE  
ADDITIONAL  
DELAY BY  
1 LINE  
Setting PVENDDELE to 1 delays vsync going low on an even  
field by a line relative to PVEND.  
PVENDSIGN, PAL Vsync End Sign, Address 0xE9 [5]  
Setting PVENDSIGN to 0 (default) delays the end of vsync. Set  
for user manual programming.  
FIELD  
TOGGLE  
Figure 42. PAL F Toggle  
Setting PVENDSIGN to 1 advances the end of vsync. Not  
recommended for user programming.  
PVEND[4:0], PAL Vsync End, Address 0xE9 [4:0]  
The default value of PVEND is 10100, indicating the PAL vsync  
end position.  
For all NTSC/PAL vsync timing controls, both the V bit in the  
AV code and the vsync on the VS pin are modified.  
Rev. A | Page 49 of 112  