Table XV. Register 48h, Serial Address Register (P ower-O n D efault = 0010 11(A1)(A0))  
Bit  
Nam e  
R/W  
D escription  
Serial Bus Address (Bits 0 and 1 are Set by A0, A1 and Bit 7 is Read Only)  
0–6  
Serial Bus Address  
Read/Write  
Table XVI. Register 49h, VID 4/D evice ID Register (P ower-O n D efault 1000000(VID 4))  
Bit  
Nam e  
R/W  
D escription  
0
VID4  
Read  
VID4 Input from Pentium®  
1–7  
Reserved  
Read/Write  
Table XVII. Register 4Bh, Tem perature Configuration Register (P ower-O n D efault = 01h)  
Bit  
Nam e  
R/W  
D escription  
0–1  
Hot T emperature  
Interrupt Mode  
Select Bits  
Read/Write  
If Bit 0 and Bit 1 of this register are both zero or one, this selects the default  
interrupt mode, which gives the user an interrupt if the temperature goes above  
the hot limit. T he interrupt will be cleared once the status register is read, but it  
will again be generated when the next conversion has completed. It will continue to  
do so until the temperature goes below the hysteresis limit.  
A 0 on Bit 1 and a 1 on Bit 0 selects the one-time interrupt mode, which gives the  
user an interrupt when the temperature goes above the hot limit. T he interrupt will  
be cleared once the status register is read. Another interrupt will not be generated  
until the temperature first goes below the hysteresis limit. No more interrupts will  
be generated until the temperature again goes above the hot limit. T he correspond-  
ing bit will be cleared in the status register every time it is read, but may not set  
again when the next conversion is done. Note that this is the power-up default  
mode.  
A 1 on Bit 1 and a 0 on Bit 0 selects the comparator mode. T his gives an INT  
when the temperature exceeds the hot limit. T his INT remains active until the  
temperature goes below the hot limit (no hysteresis), when the INT will become  
inactive.  
2–6  
7
Reserved  
T emp  
Read/Write  
Read only  
Default = 00000  
LSB of T emperature Reading = 0.5°C  
Pentium is a registered trademark of Intel Corp.  