ADE7761B  
V
R
V
1A  
F
Analog Devices cautions users of the ADE7761B about the  
following:  
CT  
IB  
RB  
RB  
C
244V rms  
POWER  
GENERATOR  
F
Billing active energy in Case 1 is consistent with the under-  
standing of the quantity represented by pulses on the CF, F1,  
and F2 outputs (watthour).  
1A  
V
1N  
0V  
C
F
Billing active energy while the ADE7761B is in Case 2 must  
be decided knowing that the entity measured by the ADE7761B  
in this case is ampere-hour and not watthour. Users should  
be aware of this limitation and decide if the ADE7761B is  
appropriate for their application.  
CT  
1
R
V
1B  
F
LOAD  
RA  
C
F
F
1
1
RB  
V
V
2P  
VR  
R
2N  
Missing Neutral Detection  
C
F
The ADE7761B continuously monitors the voltage input and  
detects a missing neutral condition when the voltage input peak  
value is smaller than 9% of the analog full scale or when no zero  
crossings are detected on this input (see Figure 33).  
1
RB + VR = RF.  
Figure 31. Missing Neutral System Diagram  
The ADE7761B detects a missing neutral condition by continu-  
ously monitoring the voltage channel input (V2P − V2N). The  
FAULT pin is held high when a missing neutral condition is  
detected. In this mode, the ADE7761B continues to bill the energy  
based on the signal level on the current channel (see Figure 32).  
The billing rate or frequency outputs can be adjusted by changing  
the dc level on the MISCAL pin.  
V
MISSING  
2P  
NEUTRAL  
FILTER AND  
THRESHOLD  
V2  
ADC  
V
2N  
AGND  
|V2|  
< 9% OF FULL SCALE  
OR  
NO ZERO CROSSING ON V2  
PEAK  
V
V
V
1A  
1N  
1B  
ADC  
V
– V  
2N  
V
– V  
2N  
V – V  
2P 2N  
2P  
2P  
A > B  
HPF  
FS  
FS  
FS  
ADC  
ZERO  
CROSSING  
DETECTION  
B > A  
A B  
9% OF FS  
0V  
0V  
0V  
LPF  
MISSING NEUTRAL  
GAIN ADJUSMTENT  
MISCAL  
ADC  
DIGITAL-TO-  
FREQUENCY  
CONVERTERS  
Figure 33. Missing Neutral Detection  
The ADE7761B leaves the missing neutral mode for normal  
operation when both conditions are no longer valid; that is,  
a voltage peak value of greater than 9% of full scale and zero  
crossing on the voltage channel is detected (see Figure 34).  
F1 F2  
CF  
Figure 32. Energy Calculation in Missing Neutral Mode  
Important Note for Billing of Active Energy  
V
MISSING  
2P  
NEUTRAL  
The ADE7761B provides pulse outputs, CF, F1, and F2, that are  
intended to be used for the billing of active energy. Pulses are  
generated at these outputs in two different situations.  
FILTER AND  
THRESHOLD  
V2  
ADC  
V
2N  
AGND  
Case 1  
|V2|  
PEAK  
> 9% OF FULL SCALE  
AND  
When the analog input V2P − V2N complies with the conditions  
described in Figure 34, the CF, F1, and F2 frequencies are propor-  
tional to active power and can be used to bill active energy.  
ZERO CROSSING ON V2  
V
– V  
2N  
2P  
FS  
Case 2  
+9% OF FS  
–9% OF FS  
When the analog input V2P − V2N does not comply with the  
conditions described in Figure 34, the ADE7761B does not  
measure active energy but a quantity proportional to kAh. This  
quantity is used to generate pulses on the same CF, F1, and F2.  
This situation is indicated when the FAULT pin is high.  
Figure 34. Return to Normal Mode After Missing Neutral Detection  
Rev. 0 | Page 19 of 24