AD9228  
ABSOLUTE MAXIMUM RATINGS  
Table 5.  
Stresses above those listed under Absolute Maximum Ratings  
may cause permanent damage to the device. This is a stress  
rating only; functional operation of the device at these or any  
other conditions above those indicated in the operational  
section of this specification is not implied. Exposure to absolute  
maximum rating conditions for extended periods may affect  
device reliability.  
With  
Respect To  
Parameter  
ELECTRICAL  
AVDD  
DRVDD  
AGND  
AVDD  
Digital Outputs  
(D+, D−, DCO+,  
DCO−, FCO+, FCO−)  
CLK+, CLK−  
VIN+, VIN−  
SDIO/ODM  
PDWN, SCLK/DTP, CSB  
REFT, REFB, RBIAS  
VREF, SENSE  
Rating  
AGND  
−0.3 V to +2.0 V  
−0.3 V to +2.0 V  
−0.3 V to +0.3 V  
−2.0 V to +2.0 V  
−0.3 V to +2.0 V  
DRGND  
DRGND  
DRVDD  
DRGND  
THERMAL IMPEDANCE  
Table 6.  
Air Flow Velocity (m/s)  
1
θJA  
θJB  
θJC  
AGND  
AGND  
AGND  
AGND  
AGND  
AGND  
−0.3 V to +3.9 V  
−0.3 V to +2.0 V  
−0.3 V to +2.0 V  
−0.3 V to +3.9 V  
−0.3 V to +2.0 V  
−0.3 V to +2.0 V  
0.0  
1.0  
2.5  
2ꢁ°C/W  
21°C/W  
19°C/W  
12.ꢃ°C/W  
1.2°C/W  
1 θJA for a ꢁ-layer PCB with solid ground plane (simulated). Exposed pad  
soldered to PCB.  
ENVIRONMENTAL  
Operating Temperature  
Range (Ambient)  
Maximum Junction  
Temperature  
−ꢁ0°C to +ꢀ5°C  
150°C  
Lead Temperature  
(Soldering, 10 sec)  
300°C  
Storage Temperature  
Range (Ambient)  
−ꢃ5°C to +150°C  
ESD CAUTION  
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as ꢁ000 V readily accumulate on  
the human body and test equipment and can discharge without detection. Although this product features  
proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy  
electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance  
degradation or loss of functionality.  
Rev. 0 | Page 9 of 52  
 