ACT5880
Rev 2, 03-Sep-13
STEP-UP DC/DC ELECTRICAL CHARACTERISTICS
(VPOWER = 3.6V, TA = 25°C, unless otherwise specified.)
PARAMETER
Operating Voltage Range
UVLO
CONDITIONS
MIN
2.7
TYP
MAX
6
UNIT
VVBAT
VVBAT
V
2.5
2.6
2.7
UVLO Hysteresis
100
mV
V
Output Programming Range
3
41.4
3
Output Voltage Accuracy
Maximum Load Current
FB3 Feedback Voltage
FB3 Input Current
IOUT=10mA.
-3
%
A
VPOWER=4.2V, VOUT3=5V, Voltage regulation option.
0.5
/
/
mV
nA
Not available in voltage regulation mode,
contact Active-semi for more details.
From the I2C last bit latched or PWRHLD set 1 to
output changes.
Turn-On Propagation Delay
150
200
2
µs
Time between 2 intersection points of the ramp
slope and 2 voltages; 0% and 100% of the final, no
and full load.
Soft Start Ramp Time,
voltage regulation option.
Normal operation, is the system oscillator
frequency.
Switch Frequency
1.8
2.2
90
MHz
ns
Minimum Off-Time
Minimum On-Time
Efficiency
40
75
Voltage regulation option, VOUT3=5V, Load=200mA.
OK[ ] asserts 0
90
%
A
Switch Current Limit
0.75
OK Threshold to Normal
Ratio
93
%
No Load Current
Switch in operation
Switch stops
1300
80
µA
Shutdown Current
Note:
1
The VPOWER is the voltage input that the Step-up DC/DC inductor connects to.
See the TYPICAL PERFORMANCE CHARACTERISTICS for:
The REG3 Start up Waveform, Full Load.
The REG3 Step Transition Response, Full Load.
The REG3 Efficiency Plot.
The REG3 Load Transition Response.
The REG3 External PWM Modulation to Current.
www.active-semi.com
Copyright © 2013 Active-Semi, Inc.
Active-Semi Confidential―Do Not Copy or Distribute
ActivePMUTM and ActivePathTM are trademarks of Active-Semi.
I2CTM is a trademark of NXP.
- 48 -