 浏览型号5962-0421901QUA的Datasheet PDF文件第168页浏览型号5962-0421901QUA的Datasheet PDF文件第169页浏览型号5962-0421901QUA的Datasheet PDF文件第170页浏览型号5962-0421901QUA的Datasheet PDF文件第171页浏览型号5962-0421901QUA的Datasheet PDF文件第173页浏览型号5962-0421901QUA的Datasheet PDF文件第174页浏览型号5962-0421901QUA的Datasheet PDF文件第175页浏览型号5962-0421901QUA的Datasheet PDF文件第176页  
MIL-PRF-38535K  
APPENDIX H  
c. Process qualification.  
(1) Test vehicle.  
(2) Single or 1 lot.  
(3) Environmental conditions (for fabrication, test, assembly, and storage).  
(4) Accept/reject criteria.  
(5) Perceptivity of tests (TCV and test programs shall be capable of highlighting the critical parameters and  
discerning the results that identify accept/reject criteria).  
(6) Process baselined for qualification ( no further changes required after characterization).  
(7) Qualification by test, similarity, or space heritage (Process or device that has been produced and passed space  
level testing and has flown in a space environment similar to the environment expected for this process/device).  
d. Fabrication.  
(1) TRB program (or equivalent) (see G.3.2.2).  
(2) SPC and in-process monitoring program (see H.3.2.1.3).  
e. Radiation hardness assurance (RHA) (see appendix C), if applicable.  
H.3.2.1.3 SPC and in-process monitoring program. An in-process monitoring system should be used by the manufacturer  
to control key processing steps to insure device yield, reliability, and RHA if applicable. The monitoring system can utilize  
various test structures, methods, and measurement techniques. The critical operations to be monitored should be determined  
by the manufacturer based on their experience and knowledge of their processes. The resulting data should be analyzed by  
appropriate SPC methods (in accordance with the requirements of TechAmerica EIA557 to determine control effectiveness.  
The following should be addressed for the wafer fabrication process, as a minimum, by the manufacturer:  
a. Incoming mask and fabrication process materials.  
b. Equipment used for wafer fabrication.  
c. Doping material concentration.  
d. Cross section diffusion or concentration profile, and epitaxial (EPI) layer.  
e. Passivation or glassivation.  
f. Metallization deposition.  
g. Resultant line width.  
h. Passivation process temperature and time.  
i. Diffusion, implant anneal process temperature, and time, or both.  
j. Sintering or annealing temperature and time.  
k. All reliability test data including the standard evaluation circuit (SEC).  
l. Mask inspection and defect density data.  
m. Parametric monitor test data.  
n. Photoresistive processing (including rework procedures).  