ST90158 - MULTIFUNCTION TIMER (MFT)
MULTIFUNCTION TIMER (Cont’d)
CAPTURE LOAD 0 HIGH REGISTER (REG0HR)
COMPARE 0 HIGH REGISTER (CMP0HR)
R240 - Read/Write
Register Page: 10
Reset value: undefined
R244 - Read/Write
Register Page: 10
Reset value: 0000 0000 (00h)
7
0
7
0
R15 R14 R13 R12 R11 R10
R9
R8
R15 R14 R13 R12 R11 R10
R9
R8
This register is used to capture values from the
Up/Down counter or load preset values (MSB).
This register is used to store the MSB of the 16-bit
value to be compared to the Up/Down counter
content.
CAPTURE LOAD 0 LOW REGISTER (REG0LR)
COMPARE 0 LOW REGISTER (CMP0LR)
R241 - Read/Write
Register Page: 10
R245 - Read/Write
Reset value: undefined
Register Page: 10
Reset value: 0000 0000 (00h)
7
0
7
0
R7
R6
R5
R4
R3
R2
R1
R0
R7
R6
R5
R4
R3
R2
R1
R0
This register is used to capture values from the
Up/Down counter or load preset values (LSB).
This register is used to store the LSB of the 16-bit
value to be compared to the Up/Down counter
content.
CAPTURE LOAD 1 HIGH REGISTER (REG1HR)
R242 - Read/Write
Register Page: 10
Reset value: undefined
COMPARE 1 HIGH REGISTER (CMP1HR)
R246 - Read/Write
Register Page: 10
Reset value: 0000 0000 (00h)
7
0
R15 R14 R13 R12 R11 R10
R9
R8
7
0
R15 R14 R13 R12 R11 R10
R9
R8
This register is used to capture values from the
Up/Down counter or load preset values (MSB).
This register is used to store the MSB of the 16-bit
value to be compared to the Up/Down counter
content.
CAPTURE LOAD 1 LOW REGISTER (REG1LR)
R243 - Read/Write
Register Page: 10
Reset value: undefined
COMPARE 1 LOW REGISTER (CMP1LR)
R247 - Read/Write
Register Page: 10
7
0
Reset value: 0000 0000 (00h)
R7
R6
R5
R4
R3
R2
R1
R0
7
0
This register is used to capture values from the
Up/Down counter or load preset values (LSB).
R7
R6
R5
R4
R3
R2
R1
R0
This register is used to store the LSB of the 16-bit
value to be compared to the Up/Down counter
content.
120/199
9