can be used, the test circuit in Figure 1 on page 4 is  
adequate. In addition, an off-hook sequence must be  
performed to connect the power source to the line-side  
chip.  
Revision Identification  
The Si3035 provides the system designer the ability to  
determine the revision of the Si3021 and/or the Si3012.  
Register 11 identifies the revision of the Si3021 with 4  
bits named REVA. Register 13 identifies the revision of  
the Si3012 with 4 bits named REVB. Table 19 shows  
the values for the various revisions.  
For the start-up test mode, no line-side power is  
necessary and no off-hook sequence is required. The  
start-up test mode is enabled by default. When the PDL  
bit (Register 6, bit 4) is set (the default case), the line  
side is in a power-down mode and the DSP-side is in a  
digital loop-back mode. In this mode, data received on  
SDI is passed through the internal filters and  
transmitted on SDO. This path will introduce  
approximately 0.9 dB of attenuation on the SDI signal  
received. The group delay of both transmit and receive  
filters will exist between SDI and SDO. Clearing the  
PDL bit disables this mode and the SDO data is  
switched to the receive data from the line side. When  
the PDL bit is cleared the FDT bit (Register 12, bit 6) will  
Table 19. Revision Values  
Revision  
Si3021  
1000  
1001  
1010  
Si3012  
A
B
C
D
E
G
0100  
0101  
0111  
become  
active,  
indicating  
the  
successful  
communication between the line-side and DSP-side.  
This can be used to verify that the ISOcap link is  
operational.  
The remaining test modes require an off-hook sequence  
to operate. The following sequence defines the off-hook  
Calibration  
The Si3035 initiates an auto-calibration by default requirement:  
whenever the device goes off-hook or experiences a  
loss in line power. Calibration is used to remove any  
offsets that may be present in the on-chip A/D converter  
which could affect the A/D dynamic range.  
Auto-calibration is typically initiated after the DAA DC  
termination stabilizes and takes 512/Fs seconds to  
complete. Due to the large variation in line conditions  
and line card behavior that may be presented to the  
DAA, it can be beneficial to use manual calibration in  
lieu of auto-calibration. Manual calibration should be  
executed as close as possible to 512/Fs seconds before  
valid transmit/receive data is expected.  
1. Power up or reset.  
2. Program clock generator to desired sample rate.  
3. Enable line-side by clearing PDL bit.  
4. Issue off-hook  
5. Delay 1548/Fs to allow calibration to occur.  
6. Set desired test mode.  
The ISOcap digital loopback mode allows the data  
pump to provide a digital input test pattern on SDI and  
receive that digital test pattern back on SDO. To enable  
this mode, set the DL bit of Register 1. In this mode, the  
isolation barrier is actually being tested. The digital  
The following steps should be taken to implement stream is delivered across the isolation capacitor, C1 of  
manual calibration:  
Figure 16 on page 15, to the line-side device and  
returned across the same barrier. In this mode, the  
0.9 dB attenuation and filter group delays also exist.  
1. The CALD (auto-calibration disable—Register 17) bit must  
be set to 1.  
The analog loopback mode allows an external device to  
drive the RX pin of the line-side chip and receive the  
signal from the TX pin. This mode allows testing of  
external components connecting the RJ-11 jack (TIP  
and RING) to the line side of the Si3035. To enable this  
mode, set the AL bit of Register 2.  
2. The MCAL (manual calibration) bit must be toggled to 1  
and then 0 to begin and complete the calibration.  
3. The calibration will be completed in 512/Fs seconds.  
In-Circuit Testing  
The Si3035’s advanced design provides the modem  
manufacturer with an increased ability to determine  
system functionality during production line tests, as well  
as support for end-user diagnostics. Four loopback  
modes exist allowing increased coverage of system  
components. For three of the test modes, a line-side  
power source is needed. While a standard phone line  
The final testing mode, internal analog loopback, allows  
the system to test the basic operation of the  
transmit/receive path of the line side and the external  
components R4, R18, R21, and C5 of Figure 16 on  
page 15. In this test mode, the data pump provides a  
32  
Rev. 1.2  