 浏览型号Z8F012APB020SC的Datasheet PDF文件第185页浏览型号Z8F012APB020SC的Datasheet PDF文件第186页浏览型号Z8F012APB020SC的Datasheet PDF文件第187页浏览型号Z8F012APB020SC的Datasheet PDF文件第188页浏览型号Z8F012APB020SC的Datasheet PDF文件第190页浏览型号Z8F012APB020SC的Datasheet PDF文件第191页浏览型号Z8F012APB020SC的Datasheet PDF文件第192页浏览型号Z8F012APB020SC的Datasheet PDF文件第193页  
Z8 Encore! XP® 4K Series  
Product Specification  
170  
Power-on reset  
Voltage Brown-Out reset  
Watch-Dog Timer reset  
Asserting the RESET pin Low to initiate a Reset.  
Driving the DBG pin Low while the device is in STOP mode initiates a System Reset.  
OCD Data Format  
The OCD interface uses the asynchronous data format defined for RS-232. Each character  
is transmitted as 1 Start bit, 8 data bits (least-significant bit first), and 1.5 Stop bits as  
shown in Figure 26.  
START  
D0  
D1  
D2  
D3  
D4  
D5  
D6  
D7  
STOP  
Figure 26.OCD Data Format  
OCD Auto-Baud Detector/Generator  
To run over a range of baud rates (data bits per second) with various system clock frequen-  
cies, the On-Chip Debugger contains an Auto-Baud Detector/Generator. After a reset, the  
OCD is idle until it receives data. The OCD requires that the first character sent from the  
host is the character 80H. The character 80Hhas eight continuous bits Low (one Start bit  
plus 7 data bits), framed between High bits. The Auto-Baud Detector measures this period  
and sets the OCD Baud Rate Generator accordingly.  
The Auto-Baud Detector/Generator is clocked by the system clock. The minimum baud  
rate is the system clock frequency divided by 512. For optimal operation with asynchro-  
nous datastreams, the maximum recommended baud rate is the system clock frequency  
divided by 8. The maximum possible baud rate for asynchronous datastreams is the sys-  
tem clock frequency divided by 4, but this theoretical maximum is possible only for low  
noise designs with clean signals. Table 108 lists minimum and recommended maximum  
baud rates for sample crystal frequencies.  
Table 108. OCD Baud-Rate Limits  
Recommended  
Recommended  
System Clock Frequency Maximum Baud Standard PC Baud Minimum Baud  
(MHz)  
Rate (Kbps)  
Rate (bps)  
Rate (Kbps)  
20.0  
2500.0  
1,843,200  
39  
PS022815-0206  
On-Chip Debugger  
 复制成功!