R
Platform Flash In-System Programmable Configuration PROMs
Symbol
Description
Clock period
(7)
(serial mode) when V
CCO
= 3.3V or 2.5V
XCF08P, XCF16P,
XCF32P
Min
30
30
35
35
12
12
12
12
2000
2000
2000
2000
12
12
8
8
–
–
–
–
0
0
0
0
0
0
–
–
5
5
3
3
3
3
300
300
–
–
–
–
–
–
30
30
Units
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
–
–
–
–
–
–
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
Max
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
35
35
35
35
2 CLK
cycles
2 CLK
cycles
2 CLK
cycles
2 CLK
cycles
T
CYCO
Clock period
(7)
(serial mode) when V
CCO
= 1.8V
Clock period
(7)
(parallel mode) when V
CCO
= 3.3V or 2.5V
Clock period
(7)
(parallel mode) when V
CCO
= 1.8V
CLK Low time
(3)
when V
CCO
= 3.3V or 2.5V
CLK Low time
(3)
when V
CCO
= 1.8V
CLK High time
(3)
when V
CCO
= 3.3V or 2.5V
CLK High time
(3)
when V
CCO
= 1.8V
CE hold time (guarantees counters are reset)
(5)
when V
CCO
= 3.3V or 2.5V
CE hold time (guarantees counters are reset)
(5)
when V
CCO
= 1.8V
OE/RESET hold time (guarantees counters are reset)
(6)
when V
CCO
= 3.3V or 2.5V
OE/RESET hold time (guarantees counters are reset)
(6)
when V
CCO
= 1.8V
BUSY setup time to CLKOUT when V
CCO
= 3.3V or 2.5V
BUSY setup time to CLKOUT when V
CCO
= 1.8V
BUSY hold time to CLKOUT when V
CCO
= 3.3V or 2.5V
BUSY hold time to CLKOUT when V
CCO
= 1.8V
CLK input to CLKOUT output delay when V
CCO
= 3.3V or 2.5V
CLK input to CLKOUT output delay when V
CCO
= 1.8V
CLK input to CLKOUT output delay when V
CCO
= 3.3V or 2.5V
with decompression
(12)
CLK input to CLKOUT output delay when V
CCO
= 1.8V
with decompression
(12)
CE to CLKOUT delay
(8)
when V
CCO
= 3.3V or 2.5V
T
LC
T
HC
T
HCE
T
HOE
T
SB
T
HB
T
CLKO
T
CECC
CE to CLKOUT delay
(8)
when V
CCO
= 1.8V
OE/RESET to CLKOUT delay
(8)
when V
CCO
= 3.3V or 2.5V
T
OECC
OE/RESET to CLKOUT delay
(8)
when V
CCO
= 1.8V
T
CFCC
T
CCDD
T
DDC
CF to CLKOUT delay
(8)
when V
CCO
= 3.3V or 2.5V
CF to CLKOUT delay
(8)
when V
CCO
= 1.8V
CLKOUT to data delay when V
CCO
= 3.3V or 2.5V
(9)
CLKOUT to data delay when V
CCO
= 1.8V
(9)
Data setup time to CLKOUT when V
CCO
= 3.3V or 2.5V with decompression
(9)(12)
Data setup time to CLKOUT when V
CCO
= 1.8V with decompression
(9)(12)
Data hold from CLKOUT when V
CCO
= 3.3V or 2.5V
T
COH
Data hold from CLKOUT when V
CCO
= 1.8V
Data hold from CLKOUT when V
CCO
= 3.3V or 2.5V with decompression
(12)
Data hold from CLKOUT when V
CCO
= 1.8V with decompression
(12)
T
SXT
EN_EXT_SEL setup time to CF, CE, or OE/RESET when V
CCO
= 3.3V or 2.5V
EN_EXT_SEL setup time to CF, CE, or OE/RESET when V
CCO
= 1.8V
DS123 (v2.17) October 26, 2009