R
Platform Flash In-System Programmable Configuration PROMS
05/07/04
(cont’d)
2.3
(cont’d)
•
•
Section DC Characteristics Over Operating Conditions, page 26:
-
Added parameter row and parameters for parallel configuration mode, ’P’
devices, to I
.
CCO
-
Added Footnote (1) and Footnote (2) with callouts in the Test Conditions column
for I , I , I , and I , to define active and standby mode
CCJ CCINTS CCOS
CCJS
requirements.
Section AC Characteristics Over Operating Conditions, page 27:
-
Corrected description for second T
parameter line to show parameters for
= 3.3V.
CAC
1.8V V
.
CCO
-
-
Revised Footnote (7) to indicate V
Applied Footnote (7) to second T
CCO
parameter line.
CYC
•
•
Section AC Characteristics Over Operating Conditions When Cascading,
page 30: Revised Footnote (5)T
Min and T
Min formulas.
CYC
CAC
Table 12, page 33:
-
-
Added additional state conditions to CLK description.
Added function of resetting the internal address counter to CF description.
07/20/04
2.4
•
•
Added Pb-free package options VOG20, FSG48, and VOG48.
Figure 8, page 14, and Figure 9, page 15: Corrected connection name for FPGA
DOUT (OPTIONAL Daisy-chained Slave FPGAs with different configurations) from
DOUT to DIN.
•
•
Section Absolute Maximum Ratings, page 24: Removed parameter T
from
SOL
table. (T
information can be found in Package User Guide.)
SOL
Table 2, page 3: Removed reference to XC2VP125 FPGA.
DS123 (v2.4) July 20, 2004
www.xilinx.com
39
Preliminary Product Specification
1-800-255-7778