R
Virtex™-II Platform FPGAs: DC and Switching Characteristics
Table 2: Recommended Operating Conditions
Symbol
Description
Internal supply voltage relative to GND, T = 0 °C to +85°C
Min
1.425
1.425
3.135
3.135
1.2
Max
1.575
1.575
3.465
3.465
3.6
Units
Commercial
Industrial
V
V
V
V
V
V
V
V
J
V
CCINT
Internal supply voltage relative to GND, T = –40°C to +100°C
J
Auxiliary supply voltage relative to GND, T = 0 °C to +85°C
Commercial
Industrial
J
V
CCAUX
Auxiliary supply voltage relative to GND, T = –40°C to +100°C
J
Supply voltage relative to GND, T = 0 °C to +85°C
Commercial
Industrial
J
V
CCO
BATT
Supply voltage relative to GND, T = –40°C to +100°C
1.2
3.6
J
Battery voltage relative to GND, T = 0 °C to +85°C
Commercial
Industrial
1.0
3.6
J
V
Battery voltage relative to GND, T = –40°C to +100°C
1.0
3.6
J
Notes:
1. If battery is not used, do not connect VBATT
2. Recommended maximum voltage droop for VCCAUX is 10 mV/ms.
.
3. The thresholds for Power On Reset are VCCINT > 1.2V, VCCAUX > 2.5V, and VCCO (Bank 4) > 1.5 V.
4. Limit the noise at the power supply to be within 200 mV peak-to-peak.
5. For power bypassing guidelines, see XAPP623 at www.xilinx.com.
Table 3: DC Characteristics Over Recommended Operating Conditions
Symbol
Description
voltage
Device
All
Min
Max Units
V
Data retention V
Data retention V
1.2
2.5
V
V
DRINT
CCINT
V
voltage
All
DRI
CCAUX
I
V
current per bank
REF
All
–10
–10
+10
+10
10
µA
µA
pF
µA
µA
nA
REF
I
Input leakage current
Input capacitance
All
L
C
All
IN
I
Pad pull-up (when selected) @ V = 0 V, V = 3.3 V (sample tested)
CCO
All
Note 1 250
Note 1 250
100
RPU
RPD
IN
I
Pad pull-down (when selected) @ V = 3.6 V (sample tested)
All
IN
I
Battery supply current
All
BATT
Notes:
1. Internal pull-up and pull-down resistors guarantee valid logic levels at unconnected input pins. These pull-up and pull-down resistors
do not guarantee valid logic levels when input pins are connected to other circuits.
DS031-3 (v3.0) August 1, 2003
Product Specification
www.xilinx.com
1-800-255-7778
Module 3 of 4
2