R
Platform Flash XL High-Density Configuration and Storage Device  
Flash Memory Architecture Overview  
Platform Flash XL is a 128-Mb (8 Mb × 16) non-volatile flash  
memory. The device is in-system programmable with a 1.8V  
be suspended to read data at any memory location except for  
the one being programmed, and then resumed.  
core (V ) power supply. A separate I/O (V  
enables I/O operation at 3.3V or 2.5V. An optional 9V V  
power supply can accelerate factory programming.  
) power supply  
DD  
DDQ  
Program and erase commands are written to the command  
interface of the memory. An internal program/erase  
controller takes care of the timing necessary for program  
and erase operations. The end of a program or erase  
operation can be detected and any error conditions  
identified in the status register. The command set required  
to control the memory is consistent with JEDEC standards.  
PP  
A common flash interface (CFI) provides access to device  
memory (Figure 3, page 3). Moreover, Platform Flash XL  
supports multiple read modes. A 23-bit address bus  
provides random read access to each 16-bit word. Four  
words occupy each page for accelerated page mode reads.  
The device powers-up in a synchronous burst read mode  
capable of sequential read rates up to 54 MHz.  
The device supports synchronous burst read and  
asynchronous read from all blocks of the memory array. At  
power-up, the device is configured for synchronous read. In  
synchronous burst read mode, data is output on each clock  
cycle at frequencies of up to 54 MHz. The synchronous  
burst read operation can be suspended and resumed.  
Platform Flash XL has a multiple-bank architecture. An array of  
131 individually erasable blocks are divided into 16, 8-Mb  
banks. Fifteen main banks contain uniform blocks of  
When the bus is inactive during asynchronous read  
operations, the device automatically switches to an  
automatic standby mode. In this condition the power  
consumption is reduced to the standby value, and the  
outputs are still driven.  
64 Kwords, and one parameter bank contains seven main  
blocks of 64 Kwords, plus four parameter blocks of 16 Kwords.  
Note: The device is electronically erasable at the block level and  
programmable on a word-by-word basis.  
The multiple-bank architecture allows dual operations —  
read operations can occur on one bank while a program or  
erase operation occurs in a different bank. However, only  
one bank at a time is allowed to be in program or erase  
mode. Burst reads are allowed to cross bank boundaries.  
Platform Flash XL features an instant, individual block-  
locking scheme, allowing any block to be locked or unlocked  
with no latency, and enabling instant code and data  
protection. All blocks have three levels of protection. Blocks  
can be locked and locked-down individually preventing any  
accidental programming or erasure. There is an additional  
Table 1 summarizes the bank architecture, and the memory  
map is shown in Figure 4, page 5. The parameter blocks are  
located at the top of the memory address space in Platform  
Flash XL.  
hardware protection against program and erase: when V  
PP  
= V  
all blocks are protected against program or erase.  
PPLK  
All blocks are locked at power-up.  
The device features a separate region of 17 programmable  
registers whose values can be protected against further  
programming changes. Sixteen of these registers are each  
Table 1: Bank Architecture  
Parameter  
Number  
Bank Size  
8 Mbits  
Main Blocks  
th  
128-bits in size, with the 17 register subdivided into two 64-  
Blocks  
bit registers. One of the 64-bit registers contains a factory  
preprogrammed, unique device number, permanently  
protected against modification. The second 64-bit register is  
user-programmable.  
Parameter  
Bank  
4 blocks of  
16 Kwords  
7 blocks of  
64 Kwords  
8 blocks of  
64 Kwords  
Bank 1  
Bank 2  
Bank 3  
8 Mbits  
All bits within these registers (except for the permanently-  
protected unique number register) are one-time-  
programmable (OTP) — each bit can be programmed only  
once from a one-value to a zero-value.  
8 blocks of  
64 Kwords  
8 Mbits  
8 blocks of  
64 Kwords  
8 Mbits  
Two protection lock registers can be programmed to lock any  
of the 17 protectable registers against further changes. One  
protection lock register contains bits that determine the  
protection state of the two special 64-bit registers. The bit  
corresponding to the unique device number register is pre-  
programmed to ensure the unique device number register is  
permanently protected against modification. The second  
protection lock register contains OTP bits that correspond  
the protection state each of the remaining 16 registers.  
8 blocks of  
64 Kwords  
Bank 14  
Bank 15  
8 Mbits  
8 Mbits  
8 blocks of  
64 Kwords  
Platform Flash XL is available in a 10 × 13 mm, 1.0 mm-pitch  
FT64 package and supplied with all the bits erased (set to '1').  
Each block can be erased separately. Erase operations can  
be suspended in order to perform a program or read operation  
in any other block and then resumed. Program operations can  
DS617 (v3.0.1) January 07, 2010  
www.xilinx.com  
Product Specification  
3