R
DC and Switching Characteristics
General Recommended Operating Conditions
Table 77: General Recommended Operating Conditions
Symbol
Description
Min
0
Nominal
Max
85
Units
° C
° C
V
T
Junction temperature
Commercial
Industrial
–
J
–40
–
1.200
-
100
V
Internal supply voltage
Output driver supply voltage
Auxiliary supply voltage
1.140
1.100
2.375
–0.5
1.260
3.465
2.625
CCINT
(1)
V
V
V
CCO
2.500
–
V
CCAUX
(2,3,4,5)
V
Input voltage extremes to avoid I/O, Input-only, and
turning on I/O protection diodes Dual-Purpose pins
V
+ 0.5
CCO
V
IN
(2)
(3)
Dedicated pins
–0.5
–
–
–
V
+ 0.5
V
CCAUX
(6)
T
Input signal transition time
500
ns
IN
Notes:
1. This V
range spans the lowest and highest operating voltages for all supported I/O standards. Table 80 lists the recommended V
CCO
CCO
range specific to each of the single-ended I/O standards, and Table 82 lists that specific to the differential standards.
2. Each of the User I/O and Dual-Purpose pins is associated with one of the four banks’ V rails. Meeting the V limit ensures that the
CCO
IN
internal diode junctions that exist between these pins and their associated V
is provided in Table 73.
and GND rails do not turn on. The absolute maximum rating
CCO
3. All Dedicated pins (PROG_B, DONE, TCK, TDI, TDO, and TMS) draw power from the V
rail (2.5V). Meeting the V max limit ensures
IN
CCAUX
that the internal diode junctions that exist between each of these pins and the V
and GND rails do not turn on.
CCAUX
4. Input voltages outside the recommended range is permissible provided that the I input clamp diode rating is met and no more than 100 pins
IK
exceed the range simultaneously. Refer to Table 73.
5. See XAPP459, "Eliminating I/O Coupling Effects when Interfacing Large-Swing Single-Ended Signals to User I/O Pins."
6. Measured between 10% and 90% V
. Follow Signal Integrity recommendations.
CCO
DS312-3 (v3.8) August 26, 2009
www.xilinx.com
119
Product Specification