R
Spartan and Spartan-XL FPGA Families Data Sheet  
to wait after completing the configuration memory clear  
operation. When INIT is no longer held Low externally, the  
device determines its configuration mode by capturing the  
state of the Mode pins, and is ready to start the configura-  
tion process. A master device waits up to an additional  
300 μs to make sure that any slaves in the optional daisy  
chain have seen that INIT is High.  
Figure 31 describes start-up timing in detail. The three  
events — DONE going High, the internal GSR being  
de-activated, and the user I/O going active — can all occur  
in any arbitrary sequence. This relative timing is selected by  
options in the bitstream generation software. Heavy lines in  
Figure 31 show the default timing. The thin lines indicate all  
other possible timing options. The start-up logic must be  
clocked until the "F" (Finished) state is reached.  
For more details on Configuration, refer to the Xilinx Appli-  
cation Note "FPGA Configuration Guidelines" (XAPP090).  
The default option, and the most practical one, is for DONE  
to go High first, disconnecting the configuration data source  
and avoiding any contention when the I/Os become active  
one clock later. GSR is then released another clock period  
later to make sure that user operation starts from stable  
internal conditions. This is the most common sequence,  
shown with heavy lines in Figure 31, but the designer can  
modify it to meet particular requirements.  
Start-Up  
Start-up is the transition from the configuration process to  
the intended user operation. This transition involves a  
change from one clock source to another, and a change  
from interfacing parallel or serial configuration data where  
most outputs are 3-stated, to normal operation with I/O pins  
active in the user system. Start-up must make sure that the  
user logic ‘wakes up’ gracefully, that the outputs become  
active without causing contention with the configuration sig-  
nals, and that the internal flip-flops are released from the  
Global Set/Reset (GSR) at the right time.  
Start-Up Clock  
Normally, the start-up sequence is controlled by the internal  
device oscillator (CCLK), which is asynchronous to the sys-  
tem clock. As a configuration option, they can be triggered  
by an on-chip user net called UCLK. This user net can be  
accessed by placing the STARTUP library symbol, and the  
start-up modes are known as UCLK_NOSYNC or  
UCLK_SYNC. This allows the device to wake up in synchro-  
nism with the user system.  
Start-Up Initiation  
Two conditions have to be met in order for the start-up  
sequence to begin:  
The chip's internal memory must be full, and  
The configuration length count must be met, exactly.  
DONE Pin  
In all configuration modes except Express mode, Spar-  
tan/XL devices read the expected length count from the bit-  
stream and store it in an internal register. The length count  
varies according to the number of devices and the composi-  
tion of the daisy chain. Each device also counts the number  
of CCLKs during configuration.  
Note that DONE is an open-drain output and does not go  
High unless an internal pull-up is activated or an external  
pull-up is attached. The internal pull-up is activated as the  
default by the bitstream generation software.  
The DONE pin can also be wire-ANDed with DONE pins of  
other FPGAs or with other external signals, and can then be  
used as input to the start-up control logic. This is called  
“Start-up Timing Synchronous to Done In” and is selected  
by either CCLK_SYNC or UCLK_SYNC. When DONE is not  
used as an input, the operation is called “Start-up Timing  
Not Synchronous to DONE In,and is selected by either  
CCLK_NOSYNC or UCLK_NOSYNC. Express mode con-  
figuration always uses either CCLK_SYNC or UCLK_SYNC  
timing, while the other configuration modes can use any of  
the four timing sequences.  
In Express mode, there is no length count. The start-up  
sequence for each device begins when the device has  
received its quota of configuration data. Wiring the DONE  
pins of several devices together delays start-up of all  
devices until all are fully configured.  
Start-Up Events  
The device can be programmed to control three start-up  
events.  
The release of the open-drain DONE output  
When the UCLK_SYNC option is enabled, the user can  
externally hold the open-drain DONE output Low, and thus  
stall all further progress in the start-up sequence until  
DONE is released and has gone High. This option can be  
used to force synchronization of several FPGAs to a com-  
mon user clock, or to guarantee that all devices are suc-  
cessfully configured before any I/Os go active.  
The termination of the Global Three-State and the  
change of configuration-related pins to the user  
function, activating all IOBs.  
The termination of the Global Set/Reset initialization of  
all CLB and IOB storage elements.  
36  
www.xilinx.com  
DS060 (v1.8) June 26, 2008  
Product Specification  