X4003/X4005
TIMING DIAGRAMS
Bus Timing
t
t
t
t
R
F
HIGH
LOW
SCL
t
SU:DAT
t
SU:STO
t
t
SU:STA
HD:DAT
t
HD:STA
SDA IN
t
t
t
BUF
A
DH
SDA OUT
WP Pin Timing
Start
SCL
Clk 1
Clk 9
Slave Address Byte
SDA IN
WP
t
t
HD:WP
SU:WP
Write Cycle Timing
SCL
SDA
8th Bit of Last Byte
ACK
t
WC
Stop
Start
Condition
Condition
Nonvolatile Write Cycle Timing
Symbol
Parameter
Write cycle time
Min.
Typ.(1)
Max.
Unit
(7)
t
5
10
ms
WC
Note: (7) t
is the time from a valid stop condition at the end of a write sequence to the end of the self-timed internal nonvolatile write cycle.
WC
It is the minimum cycle time to be allowed for any nonvolatile write by the user, unless Acknowledge Polling is used.
Characteristics subject to change without notice. 12 of 18
REV 1.1.3 4/30/02
www.xicor.com