X4003/X4005
ABSOLUTE MAXIMUM RATINGS
COMMENT
Temperature under bias ................... -65°C to +135°C
Storage temperature ........................ -65°C to +150°C
Voltage on any pin with
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only; the functional operation of
the device (at these or any other conditions above those
listed in the operational sections of this specification) is
not implied. Exposure to absolute maximum rating con-
ditions for extended periods may affect device reliability.
respect to V .......................................-1.0V to +7V
SS
D.C. output current ............................................... 5mA
Lead temperature (soldering, 10 seconds).........300°C
RECOMMENDED OPERATING CONDITIONS
Temperature
Commercial
Industrial
Min.
0°C
Max.
70°C
Option
–1.8
Supply Voltage Limits
1.8V to 3.6V
-40°C
+85°C
–2.7 and –2.7A
Blank and –4.5A
2.7V to 5.5V
4.5V to 5.5V
D.C. OPERATING CHARACTERISTICS (Over the recommended operating conditions unless otherwise specified.)
= 1.8 to 3.6V = 2.7 to 5.5V
V
V
CC
CC
Symbol
Parameter
Min
Max
Min
Max
Unit
Test Conditions
(1)
I
Active supply current
read control register
0.5
1.0
mA
f
=
SCL
CC
400kHznonvolatile,
SDA = Open
(1)
(2)
(2)
(2)
I
Active supply current
write control register
1.5
1
3.0
1
mA
µA
µA
µA
CC2
CC3
CC4
CC5
I
I
I
Operating current AC
(WDT off)
Operating current DC
(WDT off)
1
1
V
= V
= V
SDA
SCL CC
Others = GND or V
SB
Operating current DC
(WDT on)
10
20
I
Input leakage current
Output leakage current
10
10
10
10
µA
µA
V
V
= GND to V
CC
LI
IN
I
= GND to V
CC
LO
SDA
Device is in Standby(2)
(3)
V
Input LOW voltage
Input HIGH voltage
-0.5
V
x 0.3
-0.5
V x 0.3
CC
V
V
V
IL
CC
(3)
V
V
V
x 0.7 V + 0.5 V
x 0.7 V + 0.5
IH
CC
CC
CC CC
Schmitt trigger input
hysteresis fixed input level
HYS
0.2
.05 x V
0.2
.05 x V
V
related level
CC
CC
CC
V
Output LOW voltage
0.4
0.4
V
I
I
= 3.0mA (2.7–5.5V)
= 1.8mA (1.8–3.6V)
OL
OL
OL
Notes: (1) The device enters the active state after any start, and remains active until: 9 clock cycles later if the device select bits in the slave
address byte are incorrect; 200ns after a stop ending a read operation; or t after a stop ending a write operation.
WC
(2) The device goes into standby: 200ns after any stop, except those that initiate a nonvolatile write cycle; t
after a stop that initiates
WC
a nonvolatile cycle; or 9 clock cycles after any start that is not followed by the correct device select bits in the slave address byte.
(3) V min. and V max. are for reference only and are not tested.
IL
IH
Characteristics subject to change without notice. 10 of 18
REV 1.1.3 4/30/02
www.xicor.com