X40430/X40431 – Preliminary Information  
Stops and Write Modes  
Figure 13. Acknowledge Polling Sequence  
Stop conditions that terminate write operations must  
be sent by the master after sending at least 1 full data  
byte plus the subsequent ACK signal. If a stop is  
issued in the middle of a data byte, or before 1 full data  
byte plus its associated ACK is sent, then the device  
will reset itself without performing the write. The con-  
tents of the array will not be effected.  
Byte Load Completed  
by Issuing STOP.  
Enter ACK Polling  
Issue START  
Acknowledge Polling  
Issue Slave Address  
Byte (Read or Write)  
Issue STOP  
The disabling of the inputs during high voltage cycles  
can be used to take advantage of the typical 5ms write  
cycle time. Once the stop condition is issued to indi-  
cate the end of the master’s byte load operation, the  
device initiates the internal high voltage cycle.  
Acknowledge polling can be initiated immediately. To  
do this, the master issues a start condition followed by  
the Slave Address Byte for a write or read operation. If  
the device is still busy with the high voltage cycle then  
no ACK will be returned. If the device has completed  
the write operation, an ACK will be returned and the  
host can then proceed with the read or write operation.  
See Figure 13.  
NO  
ACK  
Returned?  
YES  
High Voltage Cycle  
Complete. Continue  
Command Sequence?  
Issue STOP  
NO  
YES  
Continue Normal  
Read or Write  
Serial Read Operations  
Command Sequence  
Read operations are initiated in the same manner as  
write operations with the exception that the R/W bit of  
the Slave Address Byte is set to one. There are three  
basic read operations: Current Address Reads, Ran-  
dom Reads, and Sequential Reads.  
PROCEED  
It should be noted that the ninth clock cycle of the read  
operation is not a “don’t care.” To terminate a read  
operation, the master must either issue a stop condi-  
tion during the ninth cycle or hold SDA HIGH during  
the ninth clock cycle and then issue a stop condition.  
Current Address Read  
Internally the device contains an address counter that  
maintains the address of the last word read incre-  
mented by one. Therefore, if the last read was to  
address n, the next read operation would access data  
from address n+1. On power up, the address of the  
address counter is undefined, requiring a read or write  
operation for initialization.  
Random Read  
Random read operation allows the master to access any  
memory location in the array. Prior to issuing the Slave  
Address Byte with the R/W bit set to one, the master must  
first perform a “dummy” write operation. The master  
issues the start condition and the Slave Address Byte,  
receives an acknowledge, then issues the Word Address  
Bytes. After acknowledging receipts of the Word Address  
Bytes, the master immediately issues another start condi-  
tion and the Slave Address Byte with the R/W bit set to  
one. This is followed by an acknowledge from the device  
and then by the eight bit word. The master terminates the  
read operation by not responding with an acknowledge  
and then issuing a stop condition. See Figure 15 for the  
address, acknowledge, and data transfer sequence.  
Upon receipt of the Slave Address Byte with the R/W  
bit set to one, the device issues an acknowledge and  
then transmits the eight bits of the Data Byte. The mas-  
ter terminates the read operation when it does not  
respond with an acknowledge during the ninth clock  
and then issues a stop condition. See Figure 14 for the  
address, acknowledge, and data transfer sequence.  
Characteristics subject to change without notice. 12 of 24  