Product Preview
WM8802
READ REGISTER OUTPUT CONTENTS
REGISTER
ADDRESS
DO7
DO6
DO5
DO4
DO3
DO2
DO1
DO0
CCB address: 0XEA
RXDET7
RXDET6
RXDET5
RXDET4
RXDET3
RXDET2
RXDET1
RXDET0
RXDET0
RX0 input detection
0: No input data to RX0
1: Input data to RX0
RXDET1
RXDET2
RXDET3
RXDET4
RXDET5
RXDET6
RXDET7
RX1 input detection
0: No input data to RX1
1: Input data to RX1
RX2 input detection
0: No input data to RX2
1: Input data to RX2
RX3 input detection
0: No input data to RX3
1: Input data to RX3
RX4 input detection
0: No input data to RX4
1: Input data to RX4
RX5 input detection
0: No input data to RX5
1: Input data to RX5
RX6 input detection
0: No input data to RX6
1: Input data to RX6
Modulation function output TXO data detection
0: No data to modulation function output TXO
1: Data to modulation function output TXO
For RXDET0 to RXDET7 read, RXMON must be set to High first.
PP Rev 1.1 April 2004
55
w