内容描述: 处理器电源管理子系统 [Processor Power Management Subsystem]
分类和应用:
文件页数/大小: 253 页 / 1578 K
品牌: WOLFSON [ WOLFSON MICROELECTRONICS PLC ]
 浏览型号WM8321GEFL/RV的Datasheet PDF文件第219页浏览型号WM8321GEFL/RV的Datasheet PDF文件第220页浏览型号WM8321GEFL/RV的Datasheet PDF文件第221页浏览型号WM8321GEFL/RV的Datasheet PDF文件第222页浏览型号WM8321GEFL/RV的Datasheet PDF文件第224页浏览型号WM8321GEFL/RV的Datasheet PDF文件第225页浏览型号WM8321GEFL/RV的Datasheet PDF文件第226页浏览型号WM8321GEFL/RV的Datasheet PDF文件第227页  
Production Data  
WM8321  
REGISTER  
ADDRESS  
BIT  
LABEL  
DC4_OK  
DEFAULT  
DESCRIPTION  
REFER TO  
R16526  
DC-DC4 status selected as an input to PWR_GOOD  
3
0
(408Eh)  
Power Good  
Source 1  
0 = Disabled  
1 = Enabled  
DC3_OK  
DC2_OK  
DC1_OK  
DC-DC3 status selected as an input to PWR_GOOD  
2
1
0
1
1
1
0 = Disabled  
1 = Enabled  
DC-DC2 status selected as an input to PWR_GOOD  
0 = Disabled  
1 = Enabled  
DC-DC1 status selected as an input to PWR_GOOD  
0 = Disabled  
1 = Enabled  
Register 408Eh Power Good Source 1  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
REFER TO  
R16527  
9
LDO10_OK  
1
LDO10 status selected as an input to PWR_GOOD  
(408Fh)  
Power Good  
Source 2  
0 = Disabled  
1 = Enabled  
LDO9_OK  
LDO8_OK  
LDO7_OK  
LDO6_OK  
LDO5_OK  
LDO4_OK  
LDO3_OK  
LDO2_OK  
LDO1_OK  
LDO9 status selected as an input to PWR_GOOD  
8
7
6
5
4
3
2
1
0
1
1
1
1
1
1
1
1
1
0 = Disabled  
1 = Enabled  
LDO8 status selected as an input to PWR_GOOD  
0 = Disabled  
1 = Enabled  
LDO7 status selected as an input to PWR_GOOD  
0 = Disabled  
1 = Enabled  
LDO6 status selected as an input to PWR_GOOD  
0 = Disabled  
1 = Enabled  
LDO5 status selected as an input to PWR_GOOD  
0 = Disabled  
1 = Enabled  
LDO4 status selected as an input to PWR_GOOD  
0 = Disabled  
1 = Enabled  
LDO3 status selected as an input to PWR_GOOD  
0 = Disabled  
1 = Enabled  
LDO2 status selected as an input to PWR_GOOD  
0 = Disabled  
1 = Enabled  
LDO1 status selected as an input to PWR_GOOD  
0 = Disabled  
1 = Enabled  
Register 408Fh Power Good Source 2  
PD, February 2012, Rev 4.0  