W90N745CD/W90N745CDG  
31  
30  
22  
29  
28  
20  
27  
26  
18  
25  
17  
24  
16  
POTPGT  
23  
15  
7
21  
13  
5
19  
Reserved  
14  
Reserved  
12  
OCPM  
11  
OCPM  
10  
DEVT  
9
8
NPSW  
PSWM  
6
4
3
2
1
0
NDSP  
BITS  
DESCRIPTION  
PowerOnToPowerGoodTime  
This field value is represented as the number of 2 ms intervals, which ensuring  
that the power switching is effective within 2 ms. Only bits [25:24] is implemented  
as R/W. The remaining bits are read only as ‘0’. It is not expected that these bits  
be written to anything other than 1h, but limited adjustment is provided. This field  
should be written to support system implementation. This field should always be  
written to a non-zero value.  
[31:24]  
POTPGT  
Reserved  
NOCP  
Reserved. Read/Write 0's  
[23:13]  
[12]  
NoOverCurrentProtection  
Global over-current reporting implemented in HYDRA-2. This bit should be written  
to support the external system port over-current implementation.  
0 = Over-current status is reported  
1 = Over-current status is not reported  
OverCurrentProtectionMode  
Global over-current reporting implemented in HYDRA-2. This bit should be written  
0 and is only valid when NoOverCurrentProtection is cleared.  
0 = Global Over-Current  
OCPM  
DEVT  
NPSW  
[11]  
[10]  
[9]  
1 = Individual Over-Current  
DeviceType  
table of none-4is not a compound device.  
NoPowerSwitching  
Global power switching implemented in HYDRA-2. This bit should be written to  
support the external system port power switching implementation.  
0 = Ports are power switched.  
1 = Ports are always powered on.  
PowerSwitchingMode  
Global power switching mode implemented in HYDRA-2. This bit is only valid  
when NoPowerSwitching is cleared. This bit should be written '0'.  
0 = Global Switching  
PSWM  
NDSP  
[8]  
1 = Individual Switching  
NumberDownstreamPorts  
[7:0]  
table of none-4 supports two downstream ports.  