 浏览型号VSC6134XST-01的Datasheet PDF文件第374页浏览型号VSC6134XST-01的Datasheet PDF文件第375页浏览型号VSC6134XST-01的Datasheet PDF文件第376页浏览型号VSC6134XST-01的Datasheet PDF文件第377页浏览型号VSC6134XST-01的Datasheet PDF文件第379页浏览型号VSC6134XST-01的Datasheet PDF文件第380页浏览型号VSC6134XST-01的Datasheet PDF文件第381页浏览型号VSC6134XST-01的Datasheet PDF文件第382页  
VSC6134  
Datasheet  
3.13.19 Global MPU Register 18 - Power-Down Register  
Address:  
0x012  
Register Reset Value:  
0x0073  
Table 416. Global MPU Register 18 - Power-Down Register  
Reset  
Value  
Bit  
15:8  
7
Name  
Access  
RO  
Description  
Reserved  
0x00  
0
DROP_EFEC_DEC_PWDN  
R/W  
Configuration bit used to power down the line side  
enhanced FEC decoder.  
0: EFEC decoder is not powered down.  
1: EFEC decoder is powered down.  
6
5
4
3
2
1
0
DROP_RS_DEC_PWDN  
ADD_RS_DEC_PWDN  
DROP_RS_ENC_PWDN  
ADD_SONET_PWDN  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
Configuration bit used to power down the line side  
RS decoder.  
0: Line RS decoder is not powered down.  
1: Line RS decoder is powered down.  
1
1
1
0
0
1
1
Configuration bit used to power down the client side  
RS decoder.  
0: Client RS decoder is not powered down.  
1: Client RS decoder is powered down.  
Configuration bit used to power down the client side  
RS encoder.  
0: Client RS encoder is not powered down.  
1: Client RS encoder is powered down.  
Configuration bit used to power down the add path  
SONET block.  
0: Add SONET is not powered down.  
1: Add SONET is powered down.  
DROP_SONET_PWDN  
ADD_ETHERNET_PWDN  
DROP_ETHERNET_PWDN  
Configuration bit used to power down the drop path  
SONET block.  
0: Drop SONET is not powered down.  
1: Drop SONET is powered down.  
Configuration bit used to power down the add path  
Ethernet monitor block.  
0: Add Ethernet monitor is not powered down.  
1: Add Ethernet monitor is powered down.  
Configuration bit used to power down the drop path  
Ethernet monitor block.  
0: Drop Ethernet monitor is not powered down.  
1: Drop Ethernet monitor is powered down.  