Tripath Technology, Inc. – Preliminary Technical Information
B-Cal control
Addr
7Dh
Register Name
B Cal Control
Default
D7
0
D6
0
D5
0
D4
BC4
0
D3
BC3
0
D2
BC2
0
D1
BC1
0
D0
0
0
0
0
0
The BCn control bits control the method of automatic DC calibration that will be used for individual channels.
BCn should be set to ‘1’ if a bridged output stage is being used. BCn should be cleared to ‘0’ if a single
ended output stage is being used. The BCn bits work in conjunction with the DCB bit. When DCB is set to
'1', the BCn bits that correspond to the channels that have bridged output stages connected to them should
be set to '1'. When DCB is cleared to '0', all of the BCn bits should be cleared to '0'.
34