TMCM-3214, TMCM-3215 Hardware Manual (V0.90 / 2016-JUN-27)
26
9 Operational ratings
The operational ratings show the intended or the characteristic ranges and should be used as design values.
In no case shall the maximum values be exceeded.
Symbol
+48V
Parameter
Min
Typ
Max
Unit
V
Power supply voltage input
18
24..48
53
+48V_LOGIC
Power supply voltage for on-board digital /
logic (if supplied separately)
Same as
+48V
V
supply
input
IPEAK
Motor coil current for sine wave peak
9
A
(chopper regulated, adjustable via software)
IRMS
I+24V
TENV
Continuous motor current (RMS)
6.5
A
Power supply current for driver
<< 3 x IRMS
A
Environmental temperature at 3x 6.5A RMS
motor current (no forced cooling)
-30**)
+50***)
°C
Table 9.1: General operational ratings of the module
**) limited by test equipment. Operation down to -40°C can be expected. Test included “cold” start at this temperature.
***) Test set-up / procedure: module placed inside climate chamber (Binder MK53) with approx. 53l volume. Motor placed
outside chamber moving slowly with motor current set to maximum supported by module (3x 6.5A RMS). Test duration: 24h.
Communication tested at beginning and end of test.
Symbol
Parameter
Min
Typ
Max
Unit
VREFL/R_HOME
Input voltage for stop / home switch inputs
REFL / REFR and HOME
0
5.5
V
VREFL/R_HOME_L
VREFL/R_HOME_H
Low level voltage for stop / home switch inputs
REFL / REFR and HOME
0
1.1
V
V
High level voltage for stop / home switch inputs
REFL / REFR and HOME
3.3
0
VOUT0…3
IOUT0…3
VAIN0…3
Voltage at open collector output OUT0…OUT3
5
V
A
V
Output sink current for OUT0…OUT3
1
Full scale input voltage range for analog inputs
0
10**)
AIN0…AIN3
Table 9.2 Operational ratings of I/Os
**) nominal upper input voltage which can be measured without saturation of the ADC. Max. voltage at max. ADC value will
be around 10.56V.
Copyright © 2016, TRINAMIC Motion Control GmbH & Co. KG