6.4.19.3 Latch0 Status (0x09AE)  
Bit  
Description  
ECAT  
PDI  
Reset Value  
0
Event Latch0 positive edge.  
r/-  
r/-  
0
0: Positive edge not detected or continuous  
mode  
1: Positive edge detected in single event mode  
only.  
Flag cleared by reading out Latch0 Time Posi-  
tive Edge.  
1
Event Latch0 negative edge.  
r/-  
r/-  
0
0: Negative edge not detected or continuous  
mode  
1: Negative edge detected in single event mode  
only.  
Flag cleared by reading out Latch0 Time Nega-  
tive Edge.  
2
Latch0 pin state  
Reserved  
r/-  
r/-  
r/-  
r/-  
0
0
7:3  
Table 111: Register 0x09AE (Latch0 Status)  
6.4.19.4 Latch1 Status (0x09AF)  
Bit  
Description  
ECAT  
PDI  
Reset Value  
0
Event Latch1 positive edge.  
r/-  
r/-  
0
0: Positive edge not detected or continuous  
mode  
1: Positive edge detected in single event mode  
only.  
Flag cleared by reading out Latch1 Time Posi-  
tive Edge.  
1
Event Latch1 negative edge.  
r/-  
r/-  
0
0: Negative edge not detected or continuous  
mode  
1: Negative edge detected in single event mode  
only.  
Flag cleared by reading out Latch1 Time Nega-  
tive Edge.  
2
Latch1 pin state  
Reserved  
r/-  
r/-  
r/-  
r/-  
0
0
7:3  
Table 112: Register 0x09AF (Latch1 Status)  