TMC6200 DATASHEET (Rev. 1.01 / 2018-NOV-15)
34
Charge Pump
DC-Characteristics
Symbol Conditions
Parameter
Min
Typ
Max Unit
Charge pump output voltage
VVCP-VVS
VVCP-VVS
fCP
operating
V12VOUT - V12VOUT
-
V
2
1
Charge pump voltage threshold
for undervoltage detection
Charge pump frequency
rising, using internal
5V regulator voltage
4.5
5.5
6.5
V
1/32
fCLKOSC
Linear Regulator
DC-Characteristics
VVS = VVSA = 24.0V
Parameter
Symbol Conditions
Min
Typ
5.0
Max Unit
Output voltage
V5VOUT
TJ = 25°C
4.80
5.20
V
Deviation of output voltage over V5VOUT(DEV) drivers disabled
the full temperature range
+/-5
+/-50
mV
TJ = full range
Deviation of output voltage over V5VOUT(DEV) drivers disabled,
+/-20
12.2
mV /
10V
the supply voltage
internal clock
TA = 25°C
VVSA = 10V to 30V
Output voltage
V12VOUT
operating, internal
clock
10.8
11.5
V
TJ = 25°C
Clock Oscillator and Input
Parameter
Clock oscillator frequency
(factory calibrated)
Timing-Characteristics
Symbol Conditions
Min
Typ
Max Unit
MHz
fCLKOSC
fCLKOSC
fCLKOSC
fCLK
tJ=-50°C
tJ=50°C
tJ=150°C
23.4
24.0
24.2
23
4
25
MHz
MHz
MHz
External clock frequency
(operating)
10-25
33
External clock high / low level
time
External clock timeout detection tCLKH1
in cycles of internal fCLKOSC
tCLKH
tCLKL
/
CLK driven to
0.1 VVIO / 0.9 VVIO
CLK driven high
10
32
ns
48
cycles
fCLKOSC
www.trinamic.com