TMC5161 DATASHEET (Rev. 1.01 / 2018-NOV-20)  
29  
GENERAL CONFIGURATION REGISTERS (0X00…0X0F)  
R/W  
Addr  
n
Register  
Description / bit names  
12 diag0_int_pushpull  
0:  
1:  
SWN_DIAG0 is open collector output (active low)  
Enable SWN_DIAG0 push pull output (active high)  
13 diag1_poscomp_pushpull  
0:  
SWP_DIAG1 is open collector output (active low)  
1:  
Enable SWP_DIAG1 push pull output (active high)  
14 small_hysteresis  
0:  
1:  
Hysteresis for step frequency comparison is 1/16  
Hysteresis for step frequency comparison is 1/32  
15 stop_enable  
0:  
Normal operation  
1:  
Emergency stop: ENCA_DCIN stops the sequencer  
when tied high (no steps become executed by  
the sequencer, motor goes to standstill state).  
16 direct_mode  
0:  
Normal operation  
1:  
Motor coil currents and polarity directly  
programmed via serial interface: Register XTARGET  
(0x2D) specifies signed coil A current (bits 8..0)  
and coil B current (bits 24..16). In this mode, the  
current is scaled by IHOLD setting. Velocity based  
current regulation of stealthChop is not available  
in this mode. The automatic stealthChop current  
regulation will work only for low stepper motor  
velocities.  
17 test_mode  
0:  
1:  
Normal operation  
Enable analog test output on pin ENCN_DCO.  
IHOLD[1..0] selects the function of ENCN_DCO:  
0…2: T120, DAC, VDDH  
Hint: Not for user, set to 0 for normal operation!  
Bit  
GSTAT Global status flags  
(Re-Write with ‘1’ bit to clear respective flags)  
reset  
0
1
1:  
Indicates that the IC has been reset since the last  
read access to GSTAT. All registers have been  
cleared to reset values.  
drv_err  
R+  
WC  
1:  
Indicates, that the driver has been shut down  
0x01  
3
GSTAT  
due to overtemperature or short circuit detection  
since the last read access. Read DRV_STATUS for  
details. The flag can only be cleared when the  
temperature is below the limit again.  
2
uv_cp  
1:  
Indicates an undervoltage on the charge pump.  
The driver is disabled during undervoltage. This  
flag is latched for information.  
Interface transmission counter. This register becomes  
incremented with each successful UART interface write access.  
It can be read out to check the serial transmission for lost  
data. Read accesses do not change the content. Disabled in SPI  
operation. The counter wraps around from 255 to 0.  
R
0x02  
8
IFCNT  