TMC5161 DATASHEET (Rev. 1.01 / 2018-NOV-20)  
28  
6.1 General Configuration Registers  
GENERAL CONFIGURATION REGISTERS (0X00…0X0F)  
R/W  
Addr  
n
Register  
Description / bit names  
Bit GCONF Global configuration flags  
recalibrate  
1: Zero crossing recalibration during driver disable  
(via ENN or via TOFF setting)  
0
1
faststandstill  
Timeout for step execution until standstill detection:  
1:  
Short time: 2^18 clocks  
0:  
Normal time: 2^20 clocks  
2
3
en_pwm_mode  
1: stealthChop voltage PWM mode enabled  
(depending on velocity thresholds). Switch from  
off to on state while in stand-still and at IHOLD=  
nominal IRUN current, only.  
multistep_filt  
1:  
Enable step input filtering for stealthChop  
optimization with external step source (default=1)  
4
5
shaft  
1:  
Inverse motor direction  
diag0_error (only with SD_MODE=1)  
1:  
Enable DIAG0 active on driver errors:  
Over temperature (ot), short to GND (s2g),  
undervoltage chargepump (uv_cp)  
DIAG0 always shows the reset-status, i.e. is active low  
during reset condition.  
6
7
diag0_otpw (only with SD_MODE=1)  
RW  
0x00  
17  
GCONF  
1:  
Enable DIAG0 active on driver over temperature  
prewarning (otpw)  
diag0_stall (with SD_MODE=1)  
1:  
Enable DIAG0 active on motor stall (set  
TCOOLTHRS before using this feature)  
diag0_step (with SD_MODE=0)  
0:  
1:  
DIAG0 outputs interrupt signal  
Enable DIAG0 as STEP output (dual edge  
triggered steps) for external STEP/DIR driver  
8
9
diag1_stall (with SD_MODE=1)  
1:  
Enable DIAG1 active on motor stall (set  
TCOOLTHRS before using this feature)  
diag1_dir (with SD_MODE=0)  
0:  
1:  
DIAG1 outputs position compare signal  
Enable DIAG1 as DIR output for external STEP/DIR  
driver  
diag1_index (only with SD_MODE=1)  
1:  
Enable DIAG1 active on index position (microstep  
look up table position 0)  
10 diag1_onstate (only with SD_MODE=1)  
1:  
Enable DIAG1 active when chopper is on (for the  
coil which is in the second half of the fullstep)  
11 diag1_steps_skipped (only with SD_MODE=1)  
1:  
Enable output toggle when steps are skipped in  
dcStep mode (increment of LOST_STEPS). Do not  
enable in conjunction with other DIAG1 options.  