UCC28951
www.ti.com.cn
ZHCSIQ7A –AUGUST 2018 –REVISED DECEMBER 2021
Set t
at resonant tank Peak and Valley
tABSET = t 4 - t 3
ABSET
tABSET = t 1 - t 0
QB d
QA g
Miller Plateau
tMILLER = t 2 - t1
QB
g
Miller Plateau
tMILLER = t 5 - t 4
t0 t1 t2
t3 t4 t5
图8-9. tABSET to Achieve Valley Switching at Light Loads
Copyright © 2023 Texas Instruments Incorporated
English Data Sheet: SLUSDB2
64
Submit Document Feedback
Product Folder Links: UCC28951