 浏览型号TPS1HC30BQPWPRQ1的Datasheet PDF文件第22页浏览型号TPS1HC30BQPWPRQ1的Datasheet PDF文件第23页浏览型号TPS1HC30BQPWPRQ1的Datasheet PDF文件第24页浏览型号TPS1HC30BQPWPRQ1的Datasheet PDF文件第25页浏览型号TPS1HC30BQPWPRQ1的Datasheet PDF文件第27页浏览型号TPS1HC30BQPWPRQ1的Datasheet PDF文件第28页浏览型号TPS1HC30BQPWPRQ1的Datasheet PDF文件第29页浏览型号TPS1HC30BQPWPRQ1的Datasheet PDF文件第30页  
TPS1HC30-Q1  
ZHCSP75A JULY 2022 REVISED DECEMBER 2022  
www.ti.com.cn  
condition: VVS = 13.5 V, inductance from 0.1 mH to 400 mH, R = 0 Ω, FR4 2s2p board, 2- × 70-μm copper, 2- ×  
35-μm copper, thermal pad copper area 600 mm2.  
8.3.4 Full Protections and Diagnostics  
8-1 is when DIAG_EN is enabled. When DIAG_EN is low, current sense and FLT are disabled. The output is  
in high-impedance mode. For details, refer to the following table.  
8-1. Diagnostic Enable Logic Table  
DIAG_EN IN Condition  
Protections and Diagnostics  
ON  
HIGH  
OFF  
See Fault Table  
ON  
Diagnostics disabled, protection normal  
SNS and FLT are high impedance  
LOW  
OFF  
8-2. Fault Table  
Conditions  
EN  
VOUT  
Latch  
FLT  
SNS  
Behavior  
Recovery  
L
L
x
Hi-Z  
Hi-Z  
0
Normal  
Normal  
ILOAD  
RON  
×
H
H
x
x
ILoad / Ksns Normal  
Holds the current at the current limit  
VBB –  
Overcurrent  
L
L
VSNSFH until thermal shutdown or when the  
overcurrent event is removed  
ILIM  
×
RLOAD  
Auto retries when THYS  
STG, Relative  
Thermal  
Shuts down when devices hits relative is met and it has been  
H
H/L  
L
VSNSFH  
or absolute thermal shutdown  
longer than tRETRY  
amount of time  
Shutdown,  
Absolute Thermal  
Shutdown  
Shuts down when devices hits relative Stays off until latch or  
H
H
L
H/L  
H
H
x
L
Hi-Z  
L
VSNSFH  
or absolute thermal shutdown  
enable is toggled  
Normal behavior, user can judge  
through the SNS pin output if it is an  
open load or not  
ILoad  
/
KSNS = ~0  
Open load, STB  
Reverse Polarity  
Internal pullup resistor is active. If VBB Clears when fault goes  
H
x
VSNSFH  
away  
VOUT < VOL then fault active.  
Channel turns on to lower power  
dissipation. Current into ground pin is  
limited by external ground network.  
x
x
x
x
x
8-3. Deglitch Time for Each Fault Condition  
Fault Condition  
Deglitch Time  
ILIM  
2.5 µs  
TREL  
2.5 µs  
TABS  
20 µs  
Open Load  
500 µs  
8.3.4.1 Short-Circuit and Overload Protection  
TPS1HC30-Q1 provides output short-circuit protection to ensure that the device prevents current flow in the  
event of a low impedance path to GND, removing the risk of damage or significant supply droop. The device is  