Conditions  
8-2. Fault Table (continued)  
EN  
VOUT  
Latch  
FLT  
SNS  
Behavior  
Recovery  
Shuts down when devices hits relative Auto retries when THYS  
or absolute thermal shutdown. Typical is met and it has been  
deglitch time for device to recognize  
longer than tRETRY  
overcurrent fault and begin to act on it amount of time  
is 2.5 μs. Typical deglitch time for  
device to recognize a TABS fault is 20  
μs.  
H
H/L  
L
L
VSNSFH  
STG, Relative  
Thermal  
Shutdown,  
Shuts down when devices hits relative Stays off until latch or  
or absolute thermal shutdown. Typical enable is toggled  
deglitch time for device to recognize  
overcurrent fault and begin to act on it  
is 2.5 μs. Typical deglitch time for  
Absolute Thermal  
Shutdown  
H
H/L  
H
L
VSNSFH  
device to recognize a TABS fault is 20  
μs.  
Normal behavior, user can judge  
through SNS pin output if it is an open  
load or not.  
ILoad  
/
H
L
x
H
H
x
x
x
x
Hi-Z  
KSNS = ~0  
Open load, STB  
Reverse Polarity  
Internal pullup resistor is active. If VBB Clears when fault goes  
away  
VOUT < VOL then fault active. Typical  
deglitch time before fault is indicated is  
700 μs.  
L
x
VSNSFH  
Channel turns on to lower power  
dissipation. Current into ground pin is  
limited by external ground network.  
x
8-3. Deglitch Time for Each Fault Condition  
Fault Condition  
Deglitch Time  
ILIM  
TREL  
2.5 µs  
2.5 µs  
TABS  
20 µs  
Open load  
700 µs  
8.3.4.1 Short-Circuit and Overload Protection  
TPS1HC100-Q1 provides output short-circuit protection to ensure that the device prevents current flow in the  
event of a low impedance path to GND, removing the risk of damage or significant supply droop. The device is  
ensured to protect against short-circuit events regardless of the state of the ILIM pins and with up to 28-V supply  
at 125°C.  
8-10 shows the behavior of the TPS1HC100-Q1 when the device is enabled into a short-circuit.  
Copyright © 2022 Texas Instruments Incorporated  