TMS320F28335, TMS320F28334, TMS320F28332
TMS320F28235, TMS320F28234, TMS320F28232
www.ti.com
SPRS439I–JUNE 2007–REVISED MARCH 2011
6.14.2 Synchronous Mode (USEREADY = 1, READYMODE = 0)
If the XREADY signal is sampled in the synchronous mode (USEREADY = 1, READYMODE = 0), then:
1
Lead:
LR ≥ tc(XTIM)
LW ≥ tc(XTIM)
2
Active:
AR ≥ 2 × tc(XTIM)
AW ≥ 2 × tc(XTIM)
NOTE
Restriction does not include external hardware wait states.
These requirements result in the following XTIMING register configuration restrictions :
XRDLEAD
XRDACTIVE
XRDTRAIL
XWRLEAD
XWRACTIVE
XWRTRAIL
X2TIMING
≥ 1
≥ 1
≥ 0
≥ 1
≥ 1
≥ 0
0, 1
Examples of valid and invalid timing when using synchronous XREADY:
XRDLEAD
XRDACTIVE
XRDTRAIL
XWRLEAD
XWRACTIVE
XWRTRAIL
X2TIMING
0, 1
Invalid(1)
Invalid(1)
Valid
0
1
1
0
0
1
0
0
0
0
1
1
0
0
1
0
0
0
0, 1
0, 1
(1) No hardware to detect illegal XTIMING configurations
Copyright © 2007–2011, Texas Instruments Incorporated
Electrical Specifications
151
Submit Documentation Feedback
Product Folder Link(s): TMS320F28335 TMS320F28334 TMS320F28332 TMS320F28235 TMS320F28234
TMS320F28232